Skip to content
1 viewer
BIM
Building

Three-bedroom ranch

Building ranch-3bed-2bath at revision 08df693db1d4, checked against model-2021.

These findings are a model check, not a plan review or a stamped design. The mechanical design follows the published ACCA procedure; not ACCA-approved software. No cited rule has been checked against a copy of its adopted code book, and each finding says so.
Drawing sheetsIFC4PDF plan setSchedule
Code profile
model-2021
Passed
415
Failed
0
UncheckedAn input was missing, so the rule could not be judged. An unchecked finding is never counted as a pass.
2
Unverified rulesRules whose citation and threshold have not been checked against a copy of the adopted code book.
96
Rooms
12
Sheets
7

Plan from a briefGenerates a floor plan from the brief, designs the electrical, plumbing and mechanical layers for it, and makes it the active building.

Reference ranch

ElectricalThe optional dwelling load calculation of NEC 220.82: general lighting at 3 VA a square foot, the demand factors of 220.82(B), and heating and cooling at 100 %.

General lighting
4,738 VA over 1579.4 ft²
Small appliance and laundry
3,000 VA and 1,500 VA
Demand load
19,999 VA
HVAC load
3,384 VA
Total load
23,383 VA, 97.4 A at 240.0 V
Panel
panel: 23 of 40 spaces
Leg balance
A 20,601 VA, B 20,255 VA

PlumbingFixture units are tallied from the fixtures in the document. The critical outlet is the one with the least pressure left after elevation and Hazen-Williams friction.

Water supply fixture units
18.5 (6.9 hot, 14.9 cold)
Drainage fixture units
19
Water heater
50 gal tank, 4,500 W; first hour 55 gal against a peak hour of 50 gal
Critical outlet
shower-1: 40.3 psi left, 20 psi required
Pressure budget
60 psi - 11.7 service - 2.5 climb - 5.6 friction over 73 ft = 40.3 psi

MechanicalLoads, equipment and ducts in the manner of Manual J, S and D. The design follows the published ACCA procedure; not ACCA-approved software.

Heating load
17,171 Btu/h
Cooling load
19,316 Btu/h (17,018 sensible, 2,299 latent)
Heat pump
hp-v24, variable: 24,000 Btu/h with a 0 kW strip
Ducts
0.34 in. w.c. available, 260 ft effective length, 0.131 in. per 100 ft
Ventilation
44.2 cfm required, 28.5 cfm infiltration
Design-day drift
heating 0.0 °F, cooling 7.5 °F

Code profileA model code edition, or a jurisdiction's adoption of one. A local amendment has its own rule id and cites the authority that adopted it; like every rule here it is unverified.

House and servicesWalls with their openings cut out, the roof, and the electrical, plumbing and mechanical runs coloured by system. Drag to turn the house, scroll to zoom, or pick a design day to colour the floor by temperature through 24 hours.

Sleeping Room FloorsBath & Laundry Tile FloorsLiving & Hall FloorsKitchen FloorUtility & Service FloorsExterior Walls (X-Ray Cutaway)Window Glazing & FramesDoors & ThresholdsInterior Partitions (X-Ray Cutaway)Countertops & Plumbing/Appliance Fit-OutService & Mechanical EquipmentGable Roof PlanesElectrical Service FeederSmall-Appliance Circuits (20A)Bath, Laundry & Outdoor 20A CircuitsSmoke & CO Alarm Interconnect CircuitGeneral Lighting & Receptacle CircuitsDedicated Appliance & HVAC 240V CircuitsCold Water Supply (PEX)Hot Water Supply (PEX)T&P Relief DischargeSanitary Drain & Waste (DWV)Plumbing Vent Stack SystemHVAC Supply Trunk & Branch DuctsHVAC Return Ductwork & GrilleBath, Kitchen & Whole-House Exhaust Ducts
Footprint
16.3 m by 10.5 m
Meshes
26

Drawing setEach sheet is drawn in whole millimetres from the building document, with its title block, scale and the model-check note. None is permit-ready or stamped.

Sheet
A-101 Three-bedroom ranch: Main floor floor plan
Paper and scale
A1 at 1:50
Revision
08df693db1d4
Open this sheetDXFCAD text
ext-sext-eext-next-wx12-bath1x12-closety8-bath1y14-bed1y14-closetx20-bath1x20-closetx20-hally18-bed2y18-bath2y18-kitcheny18-utilityx12-bed2-bath2x12-bed2-laundryy25-bath2x20-bath2x20-laundryx34-bed3x34-utilityx34-diningy13-bed3door-frontdoor-reardoor-bed1door-bath1door-closetdoor-bed2door-bath2door-laundrydoor-bed3door-utilitycased-hallcased-kitchencased-diningwin-bed1-swin-bath1-swin-living-s1win-living-s2win-bed3-swin-bed3-ewin-dining-nwin-kitchen-n1win-kitchen-n2win-laundry-nwin-bed2-nwin-bed2-wwin-bed1-wPrimary Bedroomprimary-bed · bedroom14.53 m²Primary Bathprimary-bath · bath5.34 m²Primary Closetprimary-closet · closet3.99 m²Hallhall · hall6.58 m²Bedroom 2bed-2 · bedroom14.53 m²Bath 2bath-2 · bath4.69 m²Laundrylaundry · laundry4.64 m²Living Roomliving · living22.21 m²Kitchenkitchen · kitchen17.15 m²Bedroom 3bed-3 · bedroom15.78 m²Utilityutility · utility5.82 m²Dining Roomdining · dining17.04 m²Three-bedroom ranch: Main floor floor planWalls drawn at finished thickness on their centrelines; corners are not cleaned up.Door hand and swing side are drawing conventions, not part of the model.Room areas are net, inside the finished faces.Dimensions in millimetres.Model check only: not permit-ready, not stamped.Dashed lines are the roof above, in plan. Roof assembly: not stated.Not drawn, the document holds only their centres: wc-1, wc-2, disposal, dishwasher, microwave, washer, dryer.counter-northcounter-west-1counter-west-2lav-1alav-1bshower-1lav-2tub-2kitchen-sinkrangerefrigeratorattic access 559 x 762crawlspace access 457 x 610roof-southroof-north(1372)(914)(2286)(610)(1219)(914)(305)(914)(458)(914)(2134)(914)(1676)(1524)(914)(3658)(914)(2744)(1220)(1829)(1980)(914)(915)(914)(1677)(610)(2286)(914)(1371)(1677)(914)(4572)(914)(1677)(14794)(9918)Three-bedroom ranch: Main floor floor planNUMBERA-101SCALE1:50UNITSmillimetresSHEETA-101 A1DATE2026-11-01DRAWNCRE8 BIMREV08df693db1d4REVISION08df693db1d4CRE8 CAD

Panel schedule

CircuitServesSpacesBreakerLoadCableRunVoltage drop
ckt-sa-1Small appliance 11420 A at 120 V1,500 VA12/2 NM-B162.1 ft6.52 %
ckt-sa-2Small appliance 21920 A at 120 V1,500 VA12/2 NM-B149.4 ft6.01 %
ckt-laundryLaundry1320 A at 120 V1,500 VA12/2 NM-B59.9 ft2.41 %
ckt-bathBathroom receptacles1520 A at 120 V1,500 VA12/2 NM-B88.2 ft3.54 %
ckt-outdoorOutdoor receptacles2220 A at 120 V540 VA12/2 NM-B127.8 ft1.85 %
ckt-alarmsSmoke alarms1815 A at 120 V900 VA14/3 NM-B133.1 ft5.11 %
ckt-general-1General 11220 A at 120 V1,753 VA12/2 NM-B545.7 ft25.65 %
ckt-general-2General 21020 A at 120 V1,780 VA12/2 NM-B442.4 ft21.11 %
ckt-general-3General 32120 A at 120 V738 VA12/2 NM-B114.7 ft2.27 %
ckt-disposalDisposal2020 A at 120 V840 VA12/2 NM-B49.5 ft1.12 %
ckt-dishwasherDishwasher1720 A at 120 V1,200 VA12/2 NM-B47.5 ft1.53 %
ckt-rangeRange1, 340 A at 240 V12,000 VA8/3 NM-B48.6 ft1.55 %
ckt-microwaveMicrowave1620 A at 120 V1,500 VA12/2 NM-B42.5 ft1.71 %
ckt-refrigeratorRefrigerator2320 A at 120 V720 VA12/2 NM-B41.5 ft0.8 %
ckt-dryerClothes dryer2, 430 A at 240 V5,000 VA10/3 NM-B58.0 ft1.22 %
ckt-air-handlerair handler9, 1115 A at 240 V576 VA14/2 NM-B33.6 ft0.21 %
ckt-heat-pumpheat pump outdoor unit6, 820 A at 240 V2,808 VA12/2 NM-B15.9 ft0.3 %
ckt-water-heater50 gal electric5, 725 A at 240 V4,500 VA10/2 NM-B25.2 ft0.48 %
18 rows

Room loads

RoomHeatingCooling, sensibleCooling, latentSolarThe part of the sensible cooling load that comes through the glass.
primary-bed1,807 Btu/h2,352 Btu/h95 Btu/h1,613 Btu/h
primary-bath561 Btu/h443 Btu/h29 Btu/h221 Btu/h
primary-closet161 Btu/h59 Btu/h0 Btu/h0 Btu/h
hall397 Btu/h165 Btu/h14 Btu/h0 Btu/h
bed-21,807 Btu/h2,195 Btu/h95 Btu/h1,480 Btu/h
bath-2190 Btu/h69 Btu/h0 Btu/h0 Btu/h
laundry532 Btu/h357 Btu/h29 Btu/h161 Btu/h
living1,888 Btu/h2,744 Btu/h851 Btu/h1,103 Btu/h
kitchen1,465 Btu/h2,371 Btu/h51 Btu/h645 Btu/h
bed-31,893 Btu/h2,082 Btu/h98 Btu/h1,311 Btu/h
utility402 Btu/h173 Btu/h17 Btu/h0 Btu/h
dining2,164 Btu/h1,695 Btu/h102 Btu/h807 Btu/h
12 rows

Code findingsEvery finding cites its code book, the adopted edition and the section. Hover a rule for its id.

DisciplineSectionThe code book, the edition this profile adopts and the section the rule cites.RuleA paraphrase of the rule's title, never the code text.ElementMeasuredRequiredStatusUnchecked means an input was missing. It is never counted as a pass.Book checkWhether the citation and the threshold have been checked against a copy of the adopted code book.Note
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areaprimary-bed22.2 sq ft12.5 sq ft (8% of 156.4 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areaprimary-bed20.0 sq ft6.3 sq ft (4% of 156.4 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustprimary-bed——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftprimary-bed156.4 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionprimary-bed11 ft 7 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryprimary-bed8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsideprimary-bedwin-bed1-s (Window)one escape opening meeting R310.2PassUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideprimary-bedwin-bed1-s: 10.0 sq ft clear, 48.0 in high, 30.0 in wide5.0 sq ft, 24.0 in high, 20.0 in widePassUnverifiedgrade-floor opening
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorprimary-bedwin-bed1-s: 24.0 in44.0 in or lessPassUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft wideprimary-bed——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areaprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areaprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustprimary-bath4.4 sq ft glazing, 3.7 sq ft openable3.0 sq ft glazing, half openable, or an exhaust fanPassUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryprimary-bath8 ft 0 in6 ft 8 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsideprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft wideprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areaprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areaprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsideprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft wideprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areahall——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areahall——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhausthall——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq fthall——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionhall——Not applicableUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryhall8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsidehall——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widehall——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorhall——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft widehall43.5 in36.0 inPassUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areabed-222.2 sq ft12.5 sq ft (8% of 156.4 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areabed-220.0 sq ft6.3 sq ft (4% of 156.4 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustbed-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftbed-2156.4 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionbed-211 ft 7 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrybed-28 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsidebed-2win-bed2-n (Window)one escape opening meeting R310.2PassUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widebed-2win-bed2-n: 10.0 sq ft clear, 48.0 in high, 30.0 in wide5.0 sq ft, 24.0 in high, 20.0 in widePassUnverifiedgrade-floor opening
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorbed-2win-bed2-n: 24.0 in44.0 in or lessPassUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft widebed-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areabath-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areabath-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustbath-2exhaust fan hvac-exh-bath-23.0 sq ft glazing, half openable, or an exhaust fanPassUnverifiedthe fan's rate is the mechanical design's to check
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftbath-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionbath-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrybath-28 ft 0 in6 ft 8 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsidebath-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widebath-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorbath-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft widebath-2——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor arealaundry——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor arealaundry——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustlaundry——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftlaundry——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionlaundry——Not applicableUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrylaundry8 ft 0 in6 ft 8 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsidelaundry——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widelaundry——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorlaundry——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft widelaundry——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor arealiving24.0 sq ft19.1 sq ft (8% of 239.0 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor arealiving11.6 sq ft9.6 sq ft (4% of 239.0 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustliving——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftliving239.0 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionliving13 ft 8 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryliving8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsideliving——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideliving——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorliving——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft wideliving——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areakitchen19.6 sq ft14.8 sq ft (8% of 184.6 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areakitchen17.5 sq ft7.4 sq ft (4% of 184.6 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustkitchen——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftkitchen——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionkitchen——Not applicableUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrykitchen8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsidekitchen——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widekitchen——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorkitchen——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft widekitchen——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areabed-322.2 sq ft13.6 sq ft (8% of 169.9 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areabed-320.0 sq ft6.8 sq ft (4% of 169.9 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustbed-3——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftbed-3169.9 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionbed-312 ft 7 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrybed-38 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsidebed-3win-bed3-s (Window)one escape opening meeting R310.2PassUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widebed-3win-bed3-s: 10.0 sq ft clear, 48.0 in high, 30.0 in wide5.0 sq ft, 24.0 in high, 20.0 in widePassUnverifiedgrade-floor opening
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorbed-3win-bed3-s: 24.0 in44.0 in or lessPassUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft widebed-3——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areautility——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areautility——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustutility——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftutility——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionutility——Not applicableUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryutility——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsideutility——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideutility——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floorutility——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft wideutility——Not applicableUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have glazing of at least 8% of floor areadining24.8 sq ft14.7 sq ft (8% of 183.5 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.1Habitable rooms have openable area of at least 4% of floor areadining12.0 sq ft7.3 sq ft (4% of 183.5 sq ft)PassUnverified
architectureInternational Residential Code 2021 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustdining——Not applicableUnverified
architectureInternational Residential Code 2021 §R304.1Habitable rooms other than kitchens have at least 70 sq ftdining183.5 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2021 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensiondining13 ft 7 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrydining8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2021 §R310.1Every sleeping room has an operable emergency escape opening to the outsidedining——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widedining——Not applicableUnverified
architectureInternational Residential Code 2021 §R310.2.2Escape opening sills are at most 44 in above the floordining——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.6Hallways are at least 3 ft widedining——Not applicableUnverified
architectureInternational Residential Code 2021 §R311.2The dwelling has a side-hinged egress door 32 in clear wide and 78 in clear highranch-3bed-2bathdoor-front: 33.0 in by 79.0 in clear32.0 in by 78.0 in clearPassUnverified
architectureInternational Residential Code 2021 §R408.4Under-floor space has access: 18 by 24 in through the floor, 16 by 24 in by wallcrawlspace18.0 in by 24.0 in18 by 24 inPassUnverified
architectureInternational Residential Code 2021 §R807.1An attic 30 in high has a 22 by 30 in access with 30 in of headroom above itattic22.0 in by 30.0 in, 97.2 in headroom22 by 30 in, 30.0 in headroomPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.11(A)Enough branch circuits for the calculated general lighting loadranch-3bed-2bath7200 VA of general-lighting circuitsat least 4738 VA (3 VA per ft2 over 1579 ft2)PassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.11(C)(1)Two or more 20-ampere small-appliance branch circuitsranch-3bed-2bath2 small-appliance circuits at 20 A2 at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.11(C)(2)A 20-ampere laundry branch circuit with no other outletsckt-laundry20 A, other outlets: none20 A, laundry receptacle outlets onlyPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.11(C)(3)A 20-ampere bathroom receptacle branch circuit with no other outletsckt-bath20 A, bathroom receptacles only20 A, bathroom receptacles only or the outlets of one bathroomPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(A)Wall receptacles so no point along the floor line is over 6 ft from oneprimary-bed5 ft 6 in from the nearest receptacle6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(A)Wall receptacles so no point along the floor line is over 6 ft from onebed-25 ft 6 in from the nearest receptacle6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(A)Wall receptacles so no point along the floor line is over 6 ft from oneliving5 ft 6 in from the nearest receptacle6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(A)Wall receptacles so no point along the floor line is over 6 ft from onekitchen2 ft 10 in from the nearest receptacle6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(A)Wall receptacles so no point along the floor line is over 6 ft from onebed-35 ft 6 in from the nearest receptacle6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(A)Wall receptacles so no point along the floor line is over 6 ft from onedining5 ft 6 in from the nearest receptacle6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(B)(1)Kitchen, dining and refrigerator receptacles on small-appliance circuitskitchennot on a small-appliance circuit: nonewall and countertop receptacles on the small-appliance circuits; refrigeration there or on its own 15 A circuitPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(B)(1)Kitchen, dining and refrigerator receptacles on small-appliance circuitsdiningnot on a small-appliance circuit: nonewall and countertop receptacles on the small-appliance circuits; refrigeration there or on its own 15 A circuitPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(B)(2)Small-appliance circuits supply no other outletsckt-sa-1other outlets: nonekitchen and dining receptacles, refrigeration and igniters onlyPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(B)(2)Small-appliance circuits supply no other outletsckt-sa-2other outlets: nonekitchen and dining receptacles, refrigeration and igniters onlyPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(B)(3)Countertop receptacles fed by two or more small-appliance circuitskitchen2 small-appliance circuits2 at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(C)Countertop receptacles so no point along the wall line is over 24 in from onecounter-north1 ft 10 in from the nearest receptacle2 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(C)Countertop receptacles so no point along the wall line is over 24 in from onecounter-west-10 ft 7 in from the nearest receptacle2 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(C)Countertop receptacles so no point along the wall line is over 24 in from onecounter-west-21 ft 1 in from the nearest receptacle2 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(D)A receptacle within 3 ft of the outside edge of each bathroom basinlav-1a0 ft 3 in from the basin's edge3 ft 0 in at most from the basin edgePassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(D)A receptacle within 3 ft of the outside edge of each bathroom basinlav-1b1 ft 10 in from the basin's edge3 ft 0 in at most from the basin edgePassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(D)A receptacle within 3 ft of the outside edge of each bathroom basinlav-20 ft 6 in from the basin's edge3 ft 0 in at most from the basin edgePassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(E)(1)Outdoor receptacles at the front and back, no higher than 6.5 ft above graderanch-3bed-2bathfront: rcpt-out-front; back: rcpt-out-backone at the front and one at the back, 6 ft 6 in at most above gradePassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(F)A receptacle where the laundry equipment goeslaundry2 receptacles in the room1 at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.52(G)Receptacles in garages and unfinished basementsranch-3bed-2bath——Not applicableUnverifiedno garage or basement
electricalNFPA 70 National Electrical Code 2020 §210.52(H)A receptacle in each hallway 10 ft or longerhall1 receptacles1 at leastPassUnverifiedhall length taken as its outline's long side, 19 ft 7 in
electricalNFPA 70 National Electrical Code 2020 §210.50(C)An appliance receptacle within 6 ft of the appliance it servesrcpt-washer1 ft 3 in from washer6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.50(C)An appliance receptacle within 6 ft of the appliance it servesrcpt-disposal1 ft 0 in from disposal6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.50(C)An appliance receptacle within 6 ft of the appliance it servesrcpt-dishwasher1 ft 0 in from dishwasher6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.50(C)An appliance receptacle within 6 ft of the appliance it servesrcpt-range1 ft 0 in from range6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.50(C)An appliance receptacle within 6 ft of the appliance it servesrcpt-microwave1 ft 0 in from microwave6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.50(C)An appliance receptacle within 6 ft of the appliance it servesrcpt-refrigerator1 ft 0 in from refrigerator6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.50(C)An appliance receptacle within 6 ft of the appliance it servesrcpt-dryer1 ft 3 in from dryer6 ft 0 in at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.63A service receptacle within 25 ft of heating and cooling equipmentair-handler2 ft 6 in to the nearest receptaclea receptacle on the same level within 25 ftPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.63A service receptacle within 25 ft of heating and cooling equipmentheat-pump2 ft 11 in to the nearest outdoor receptaclea receptacle on the same level within 25 ftPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(1)A switched lighting outlet in each habitable room, kitchen and bathroomprimary-bedlight-primary-bed, switcheda wall-switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(1)A switched lighting outlet in each habitable room, kitchen and bathroomprimary-bathlight-primary-bath, switcheda wall-switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(1)A switched lighting outlet in each habitable room, kitchen and bathroombed-2light-bed-2, switcheda wall-switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(1)A switched lighting outlet in each habitable room, kitchen and bathroombath-2light-bath-2, switcheda wall-switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(1)A switched lighting outlet in each habitable room, kitchen and bathroomlivinglight-living, switcheda wall-switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(1)A switched lighting outlet in each habitable room, kitchen and bathroomkitchenlight-kitchen, switcheda wall-switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(1)A switched lighting outlet in each habitable room, kitchen and bathroombed-3light-bed-3, switcheda wall-switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(1)A switched lighting outlet in each habitable room, kitchen and bathroomdininglight-dining, switcheda wall-switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(2)Switched lighting in hallways, stairways, garages and at outdoor entranceshalllight-hall, switcheda wall-switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(2)Switched lighting in hallways, stairways, garages and at outdoor entrancesdoor-frontlight-door-front, switcheda wall-switched lighting outlet outside the doorPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(2)Switched lighting in hallways, stairways, garages and at outdoor entrancesdoor-rearlight-door-rear, switcheda wall-switched lighting outlet outside the doorPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(3)Lighting in utility and storage spaces and where equipment needs servicingutilitylight-utility, switcheda switched lighting outletPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(3)Lighting in utility and storage spaces and where equipment needs servicingattic——Not applicableUnverifiedused for neither storage nor equipment
electricalNFPA 70 National Electrical Code 2020 §210.70(A)(3)Lighting in utility and storage spaces and where equipment needs servicingcrawlspace——Not applicableUnverifiedused for neither storage nor equipment
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-kitchen-1ground-fault protectedprotectedPassUnverifiedserves a kitchen countertop
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-kitchen-2ground-fault protectedprotectedPassUnverifiedserves a kitchen countertop
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-kitchen-3ground-fault protectedprotectedPassUnverifiedserves a kitchen countertop
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-kitchen-4ground-fault protectedprotectedPassUnverifiedserves a kitchen countertop
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-kitchen-5ground-fault protectedprotectedPassUnverifiedserves a kitchen countertop
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-kitchen-6ground-fault protectedprotectedPassUnverifiedserves a kitchen countertop
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-kitchen-7ground-fault protectedprotectedPassUnverifiedin a kitchen but not at the countertop; this crate does not settle whether 210.8(A)(6) reaches it
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-kitchen-8ground-fault protectedprotectedPassUnverifiedin a kitchen but not at the countertop; this crate does not settle whether 210.8(A)(6) reaches it
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-kitchen-9ground-fault protectedprotectedPassUnverifiedin a kitchen but not at the countertop; this crate does not settle whether 210.8(A)(6) reaches it
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-primary-bath-1ground-fault protectedprotectedPassUnverifiedin a bathroom
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-bath-2-1ground-fault protectedprotectedPassUnverifiedin a bathroom
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-washerground-fault protectedprotectedPassUnverifiedin a laundry area
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-out-frontground-fault protectedprotectedPassUnverifiedoutdoors
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-out-background-fault protectedprotectedPassUnverifiedoutdoors
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-out-heat-pumpground-fault protectedprotectedPassUnverifiedoutdoors
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-disposalground-fault protectedprotectedPassUnverifiedwithin 6 ft of sink kitchen-sink
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-dishwasherground-fault protectedprotectedPassUnverifiedwithin 6 ft of sink kitchen-sink
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-rangeground-fault protectedprotectedPassUnverifiedin a kitchen but not at the countertop; this crate does not settle whether 210.8(A)(6) reaches it
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-microwaveground-fault protectedprotectedPassUnverifiedin a kitchen but not at the countertop; this crate does not settle whether 210.8(A)(6) reaches it
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-refrigeratorground-fault protectedprotectedPassUnverifiedin a kitchen but not at the countertop; this crate does not settle whether 210.8(A)(6) reaches it
electricalNFPA 70 National Electrical Code 2020 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsrcpt-dryerground-fault protectedprotectedPassUnverifiedin a laundry area
electricalNFPA 70 National Electrical Code 2020 §210.8(D)Ground-fault protection for the dishwasher outletdishwasherckt-dishwasher dualground-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.8(F)Ground-fault protection for outdoor outlets on circuits of 50 A or lessheat-pumpground-fault protectedprotectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-sa-1protection dualarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-sa-2protection dualarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-laundryprotection dualarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-alarmsprotection afciarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-general-1protection afciarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-general-2protection afciarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-general-3protection afciarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-disposalprotection dualarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-dishwasherprotection dualarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-microwaveprotection dualarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §210.12(A)Arc-fault protection for circuits supplying living areasckt-refrigeratorprotection dualarc-fault protectedPassUnverified
electricalNFPA 70 National Electrical Code 2020 §422.10An appliance branch circuit rated for the appliance loaddisposalckt-disposal 120 V 20 A120 V, at least 7.0 APassUnverified
electricalNFPA 70 National Electrical Code 2020 §422.10An appliance branch circuit rated for the appliance loaddishwasherckt-dishwasher 120 V 20 A120 V, at least 10.0 APassUnverified
electricalNFPA 70 National Electrical Code 2020 §422.10An appliance branch circuit rated for the appliance loadrangeckt-range 240 V 40 A240 V, at least 40.0 APassUnverified
electricalNFPA 70 National Electrical Code 2020 §422.10An appliance branch circuit rated for the appliance loadmicrowaveckt-microwave 120 V 20 A120 V, at least 12.5 APassUnverified
electricalNFPA 70 National Electrical Code 2020 §422.10An appliance branch circuit rated for the appliance loadrefrigeratorckt-refrigerator 120 V 20 A120 V, at least 6.0 APassUnverified
electricalNFPA 70 National Electrical Code 2020 §422.10An appliance branch circuit rated for the appliance loaddryerckt-dryer 240 V 30 A240 V, at least 30.0 APassUnverified
electricalNFPA 70 National Electrical Code 2020 §422.12Central heating equipment on an individual branch circuitair-handlerckt-air-handleran individual branch circuitPassUnverified
electricalNFPA 70 National Electrical Code 2020 §422.13A storage water heater circuit at 125 percent of its ratingwater-heater25 A at 240 Vat least 23.4 A (125 percent of 4500 W)PassUnverified
electricalNFPA 70 National Electrical Code 2020 §110.3(B)Equipment installed and used per its listing and labelingair-handler15 A at 240 V on ckt-air-handler15 A at most at 240 V, nameplate hp-v24PassUnverified
electricalNFPA 70 National Electrical Code 2020 §110.3(B)Equipment installed and used per its listing and labelingheat-pump20 A at 240 V on ckt-heat-pump20 A at most at 240 V, nameplate hp-v24PassUnverified
electricalNFPA 70 National Electrical Code 2020 §440.32Motor-compressor branch-circuit conductors sized from the nameplateheat-pump20 A conductors14.4 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-sa-120 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-sa-112 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-sa-220 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-sa-212 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-laundry20 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-laundry12 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-bath20 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-bath12 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-outdoor20 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-outdoor12 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-alarms15 A on 14 AWG15 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-alarms14 AWG at 15 A for a 15 A breaker15 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-general-120 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-general-112 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-general-220 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-general-212 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-general-320 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-general-312 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-disposal20 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-disposal12 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-dishwasher20 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-dishwasher12 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-range——Not applicableUnverified8 AWG is larger than 10 AWG
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-range8 AWG at 40 A for a 40 A breaker40 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-microwave20 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-microwave12 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-refrigerator20 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-refrigerator12 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-dryer30 A on 10 AWG30 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-dryer10 AWG at 30 A for a 30 A breaker30 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-air-handler15 A on 14 AWG15 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-air-handler14 AWG at 15 A for a 15 A breaker15 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-heat-pump20 A on 12 AWG20 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-heat-pump12 AWG at 20 A for a 20 A breaker20 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsckt-water-heater25 A on 10 AWG30 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §Table 310.16Conductor ampacity at least the overcurrent device ratingckt-water-heater10 AWG at 30 A for a 25 A breaker25 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §220.82Dwelling load by the optional method within the service ratingel-service97.4 A100 A at mostPassUnverified
electricalNFPA 70 National Electrical Code 2020 §230.79(C)A one-family dwelling service of 100 A or moreel-service100 A100 A at leastPassUnverified
electricalNFPA 70 National Electrical Code 2020 §310.12Dwelling service conductors at 83 percent of the service ratingel-service4 AWG at 85 Aat least 83 A (83 percent of 100 A)PassUnverified
electricalNFPA 70 National Electrical Code 2020 §408.4(A)Every circuit identified in the panel directorypanelunnamed, unplaced or duplicate: noneevery circuit named once, at its spacesPassUnverified
electricalNFPA 70 National Electrical Code 2020 §408.54Overcurrent devices no more than the panel's spacespanel23 of 40 spaces used; misplaced: noneone space per pole, none shared, within the panelPassUnverified
electricalInternational Residential Code 2021 §R314.3Smoke alarms in and outside each sleeping room and on every storeyprimary-bed1 alarms1 at leastPassUnverified
electricalInternational Residential Code 2021 §R314.3Smoke alarms in and outside each sleeping room and on every storeybed-21 alarms1 at leastPassUnverified
electricalInternational Residential Code 2021 §R314.3Smoke alarms in and outside each sleeping room and on every storeybed-31 alarms1 at leastPassUnverified
electricalInternational Residential Code 2021 §R314.3Smoke alarms in and outside each sleeping room and on every storeydoor-bed1smoke-hall 2 ft 0 in from the doorin the immediate vicinityPassUnverifiedimmediate vicinity taken as 10 ft
electricalInternational Residential Code 2021 §R314.3Smoke alarms in and outside each sleeping room and on every storeydoor-bed2smoke-hall 2 ft 0 in from the doorin the immediate vicinityPassUnverifiedimmediate vicinity taken as 10 ft
electricalInternational Residential Code 2021 §R314.3Smoke alarms in and outside each sleeping room and on every storeydoor-bed3smoke-living 0 ft 0 in from the doorin the immediate vicinityPassUnverifiedimmediate vicinity taken as 10 ft
electricalInternational Residential Code 2021 §R314.3Smoke alarms in and outside each sleeping room and on every storeymain5 alarms1 on each storeyPassUnverified
electricalInternational Residential Code 2021 §R314.3 item 4Smoke alarms 3 ft or more from a bathroom door with a tub or showersmoke-primary-bed7 ft 11 in from a bathroom door3 ft 0 in at leastPassUnverified
electricalInternational Residential Code 2021 §R314.3 item 4Smoke alarms 3 ft or more from a bathroom door with a tub or showersmoke-bed-212 ft 2 in from a bathroom door3 ft 0 in at leastPassUnverified
electricalInternational Residential Code 2021 §R314.3 item 4Smoke alarms 3 ft or more from a bathroom door with a tub or showersmoke-bed-325 ft 3 in from a bathroom door3 ft 0 in at leastPassUnverified
electricalInternational Residential Code 2021 §R314.3 item 4Smoke alarms 3 ft or more from a bathroom door with a tub or showersmoke-hall6 ft 0 in from a bathroom door3 ft 0 in at leastPassUnverified
electricalInternational Residential Code 2021 §R314.3 item 4Smoke alarms 3 ft or more from a bathroom door with a tub or showersmoke-living17 ft 2 in from a bathroom door3 ft 0 in at leastPassUnverified
electricalInternational Residential Code 2021 §R314.3.1Smoke alarms kept their distance from cooking appliancessmoke-primary-bed22 ft 3 in from the cooking appliance's point6 ft 0 in at least from its edgePassUnverified
electricalInternational Residential Code 2021 §R314.3.1Smoke alarms kept their distance from cooking appliancessmoke-bed-216 ft 1 in from the cooking appliance's point6 ft 0 in at least from its edgePassUnverified
electricalInternational Residential Code 2021 §R314.3.1Smoke alarms kept their distance from cooking appliancessmoke-bed-323 ft 1 in from the cooking appliance's point6 ft 0 in at least from its edgePassUnverified
electricalInternational Residential Code 2021 §R314.3.1Smoke alarms kept their distance from cooking appliancessmoke-hall13 ft 5 in from the cooking appliance's point6 ft 0 in at least from its edgePassUnverified
electricalInternational Residential Code 2021 §R314.3.1Smoke alarms kept their distance from cooking appliancessmoke-living15 ft 5 in from the cooking appliance's point6 ft 0 in at least from its edgePassUnverified
electricalInternational Residential Code 2021 §R314.4Smoke alarms interconnected so one sounds allsmoke-primary-bedinterconnected: yesinterconnectedPassUnverified
electricalInternational Residential Code 2021 §R314.4Smoke alarms interconnected so one sounds allsmoke-bed-2interconnected: yesinterconnectedPassUnverified
electricalInternational Residential Code 2021 §R314.4Smoke alarms interconnected so one sounds allsmoke-bed-3interconnected: yesinterconnectedPassUnverified
electricalInternational Residential Code 2021 §R314.4Smoke alarms interconnected so one sounds allsmoke-hallinterconnected: yesinterconnectedPassUnverified
electricalInternational Residential Code 2021 §R314.4Smoke alarms interconnected so one sounds allsmoke-livinginterconnected: yesinterconnectedPassUnverified
electricalInternational Residential Code 2021 §R314.6Smoke alarms powered from the building wiring with battery backupsmoke-primary-bedon a branch circuit, battery backup: yesbuilding wiring with battery backupPassUnverified
electricalInternational Residential Code 2021 §R314.6Smoke alarms powered from the building wiring with battery backupsmoke-bed-2on a branch circuit, battery backup: yesbuilding wiring with battery backupPassUnverified
electricalInternational Residential Code 2021 §R314.6Smoke alarms powered from the building wiring with battery backupsmoke-bed-3on a branch circuit, battery backup: yesbuilding wiring with battery backupPassUnverified
electricalInternational Residential Code 2021 §R314.6Smoke alarms powered from the building wiring with battery backupsmoke-hallon a branch circuit, battery backup: yesbuilding wiring with battery backupPassUnverified
electricalInternational Residential Code 2021 §R314.6Smoke alarms powered from the building wiring with battery backupsmoke-livingon a branch circuit, battery backup: yesbuilding wiring with battery backupPassUnverified
electricalInternational Residential Code 2021 §R315.3Carbon monoxide alarms outside sleeping rooms where requiredranch-3bed-2bath——Not applicableUnverifiedno fuel-burning appliance or attached garage
plumbingInternational Residential Code 2021 §P2903.3Static pressure at the service is at least 40 psiwater-service60 psi static40 psi at leastPassUnverified
plumbingInternational Residential Code 2021 §P2903.3.1Static pressure over 80 psi is cut by a pressure-reducing valvewater-service60 psi static80 psi at most, or a pressure-reducing valvePassUnverified
plumbingInternational Residential Code 2021 §P2903.4Thermal expansion is controlled where the supply cannot push back to the mainexpansion-tankexpansion-tankan expansion controlPassUnverified
plumbingInternational Residential Code 2021 §P2903.5Quick-closing valves have water hammer arrestorsdishwasherhammer-arrestor-dishwasheran arrestorPassUnverified
plumbingInternational Residential Code 2021 §P2903.5Quick-closing valves have water hammer arrestorswasherhammer-arrestor-washeran arrestorPassUnverified
plumbingInternational Residential Code 2021 §P2903.9.1A full-open valve on the water service near where it enterswater-serviceservice-valvea full-open valvePassUnverified
plumbingInternational Residential Code 2021 §P2903.9.2A full-open valve on the cold supply to the water heaterwater-heaterheater-valvea full-open valvePassUnverified
plumbingInternational Residential Code 2021 §P2903.7The water service is at least 3/4 incold-service1 in3/4 inPassUnverified
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-service1 in for 18.5 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-11 in for 16.0 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-21 in for 12.4 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-31 in for 11.4 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-41 in for 9.2 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-51 in for 8.2 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-61 in for 7.7 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-71 in for 6.7 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-83/4 in for 6.2 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-93/4 in for 5.2 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-103/4 in for 4.7 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-113/4 in for 2.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-lav-1a1/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-lav-1b1/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-wc-13/4 in for 2.2 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-shower-11/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-lav-21/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-wc-23/4 in for 2.2 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-tub-21/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-kitchen-sink1/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-washer1/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-hose-bibb-w3/4 in for 2.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-hose-bibb-e3/4 in for 2.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-water-heater1 in for 6.9 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-heater1 in for 6.9 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-11 in for 6.9 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-23/4 in for 5.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-33/4 in for 4.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-43/4 in for 3.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-53/4 in for 3.0 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-63/4 in for 2.0 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-71/2 in for 1.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-81/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-lav-1a1/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-lav-1b1/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-shower-11/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-lav-21/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-tub-21/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-kitchen-sink1/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-dishwasher1/2 in for 1.4 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-washer1/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter
plumbingInternational Residential Code 2021 §P2903.7The developed length from the meter fits the size column usedcold-water132 ft from the meter200 ft for a 3/4 in meter and 1 in servicePassUnverified
plumbingInternational Residential Code 2021 §P2903.1Each outlet gets its tabulated flow at its tabulated pressurewasher39.0 psi hot8 psi at leastPassUnverifiedthe most remote outlet: 60 psi - 11.7 service - 1.1 climb - 8.2 friction over 82 ft = 39.0 psi
plumbingInternational Residential Code 2021 §P2903.1Each outlet gets its tabulated flow at its tabulated pressureshower-140.3 psi hot20 psi at leastPassUnverifiedthe least-margin outlet: 60 psi - 11.7 service - 2.5 climb - 5.6 friction over 73 ft = 40.3 psi
plumbingInternational Residential Code 2021 §P2801.1Hot water outlets are served by a water heaterwater-heater50 gal tank, 55 gal first hour for a 50 gal peak hourthe hot supply starts at the heaterPassUnverifiedtank size is design practice; the IRC sets none
plumbingInternational Residential Code 2021 §P2804.1A storage water heater has pressure and temperature reliefwater-heaterrelief-valvea temperature and pressure relief valvePassUnverified
plumbingInternational Residential Code 2021 §P2804.3Pressure relief opens at no more than 150 psirelief-valve150 psi150 psi at mostPassUnverified
plumbingInternational Residential Code 2021 §P2804.4Temperature relief opens at no more than 210 F and senses the top 6 in of the tankrelief-valve210 F, sensing 102 mm below the top210 F at most, sensing within 152 mm of the topPassUnverified
plumbingInternational Residential Code 2021 §P2804.6.1Relief discharge is full size, never rises and ends no more than 6 in above the floorrelief-line3/4 in ending 150 mm above the floor3/4 in at least, falling, ending within 152 mmPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-10.270 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-20.258 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-30.253 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-40.480 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-50.253 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-60.255 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-70.333 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-80.250 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-lav-1a0.267 in/ft1/4 in/ft at least for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-lav-1b0.300 in/ft1/4 in/ft at least for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-wc-10.264 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-shower-10.267 in/ft1/4 in/ft at least for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-lav-20.267 in/ft1/4 in/ft at least for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-wc-20.267 in/ft1/8 in/ft at least for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-tub-20.293 in/ft1/4 in/ft at least for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-kitchen-sink0.250 in/ft1/4 in/ft at least for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-dishwasher0.251 in/ft1/4 in/ft at least for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-washer0.267 in/ft1/4 in/ft at least for 2 inPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizelav-1a1-1/2 in for 1 dfu1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizelav-1b1-1/2 in for 1 dfu1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizewc-13 in for 3 dfu3 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizeshower-11-1/2 in for 2 dfu1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizelav-21-1/2 in for 1 dfu1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizewc-23 in for 3 dfu3 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizetub-21-1/2 in for 2 dfu1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizekitchen-sink1-1/2 in for 2 dfu1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizedishwasher1-1/2 in for 2 dfu1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizewasher2 in for 2 dfu1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-13 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-25 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-37 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-48 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-511 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-613 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-715 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverified
plumbingInternational Residential Code 2021 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-819 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverified
plumbingInternational Residential Code 2021 §P3005.2Cleanouts on a horizontal drain are at most 100 ft apartbuilding-drain-131.2 ft longest stretch100 ft at most between cleanoutsPassUnverified2 cleanouts along 32.2 ft of drain
plumbingInternational Residential Code 2021 §P3005.2A cleanout at each horizontal change of direction over 45 degreesdwv——Not applicableUnverifiedno horizontal drain turns more than 45 degrees
plumbingInternational Residential Code 2021 §P3005.2A cleanout within 10 ft of where the building drain meets the sewersewer317 mm to a cleanouta cleanout within 10 ftPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a ventlav-1avent-lav-1aa vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the ventlav-1a1.5 ft6 ft at most for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a ventlav-1bvent-lav-1ba vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the ventlav-1b0.7 ft6 ft at most for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a ventwc-1vent-wc-1a vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the ventwc-11.5 ft12 ft at most for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a ventshower-1vent-shower-1a vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the ventshower-11.5 ft6 ft at most for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a ventlav-2vent-lav-2a vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the ventlav-21.5 ft6 ft at most for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a ventwc-2vent-wc-2a vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the ventwc-21.5 ft12 ft at most for 3 inPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a venttub-2vent-tub-2a vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the venttub-20.4 ft6 ft at most for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a ventkitchen-sinkvent-kitchen-sinka vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the ventkitchen-sink1.5 ft6 ft at most for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a ventdishwashervent-dishwashera vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the ventdishwasher1.5 ft6 ft at most for 1-1/2 inPassUnverified
plumbingInternational Residential Code 2021 §P3101.2Every trap seal is protected by a ventwashervent-washera vent on its drainPassUnverified
plumbingInternational Residential Code 2021 §P3105.1A trap arm is no longer than its size allows before the ventwasher1.5 ft8 ft at most for 2 inPassUnverified
plumbingInternational Residential Code 2021 §P3102.1At least one vent extends to the outdoorsventvent-washer ends 600 mm over the roofthrough the roofPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-lav-1a1-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-lav-1b1-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-wc-11-1/2 in1-1/2 in at least for a 3 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-shower-11-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-lav-21-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-wc-21-1/2 in1-1/2 in at least for a 3 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-tub-21-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-kitchen-sink1-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-dishwasher1-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-washer1-1/4 in1-1/4 in at least for a 2 in drainPassUnverified
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizelav-1a1-1/4 in1-1/4 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizelav-1b1-1/4 in1-1/4 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizewc-1——Not applicableUnverifiedthe trap is part of the fixture
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizeshower-11-1/2 in1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizelav-21-1/4 in1-1/4 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizewc-2——Not applicableUnverifiedthe trap is part of the fixture
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizetub-21-1/2 in1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizekitchen-sink1-1/2 in1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizedishwasher1-1/2 in1-1/2 in at leastPassUnverified
plumbingInternational Residential Code 2021 §P3201.7A fixture trap is at least its tabulated sizewasher2 in2 in at leastPassUnverified
mechanicalInternational Residential Code 2021 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tablewindow-double-low-eU 0.280U <= 0.300 (fenestration, zone 4A)PassUnverified
mechanicalInternational Residential Code 2021 §N1102.1.2Glazed fenestration meets the climate zone's SHGCwindow-double-low-eSHGC 0.28SHGC <= 0.40 (zone 4A)PassUnverified
mechanicalInternational Residential Code 2021 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tablewall-2x6-r20U 0.060U <= 0.060 (frame wall, zone 4A)PassUnverified
mechanicalInternational Residential Code 2021 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tableceiling-r60U 0.024U <= 0.024 (ceiling, zone 4A)PassUnverified
mechanicalInternational Residential Code 2021 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tablefloor-r19U 0.047U <= 0.047 (floor, zone 4A)PassUnverified
mechanicalInternational Residential Code 2021 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tabledoor-insulated-steelU 0.200U <= 0.300 (fenestration (doors count as fenestration), zone 4A)PassUnverified
mechanicalInternational Residential Code 2021 §N1102.4.1.2Tested air leakage is no more than the zone's ACH50ranch-3bed-2bathno tested or target leakageACH50 <= 3.0UncheckedUnverifiedthe loads assume the zone's maximum
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computableprimary-bedheating 1807 Btu/h, cooling sensible 2352 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computableprimary-bathheating 561 Btu/h, cooling sensible 443 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computableprimary-closetheating 161 Btu/h, cooling sensible 59 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablehallheating 397 Btu/h, cooling sensible 165 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablebed-2heating 1807 Btu/h, cooling sensible 2195 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablebath-2heating 190 Btu/h, cooling sensible 69 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablelaundryheating 532 Btu/h, cooling sensible 357 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablelivingheating 1888 Btu/h, cooling sensible 2744 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablekitchenheating 1465 Btu/h, cooling sensible 2371 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablebed-3heating 1893 Btu/h, cooling sensible 2082 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computableutilityheating 402 Btu/h, cooling sensible 173 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablediningheating 2164 Btu/h, cooling sensible 1695 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1401.3Heating equipment is sized to ACCA Manual S on Manual J loadshvac20000 Btu/h at 17 F (20000 heat pump + 0 kW strip)17171 Btu/h heating loadPassUnverifiedunit hp-v24; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1401.3Cooling equipment is sized to ACCA Manual S on Manual J loadshvac24576 Btu/h total at 92 F, 127% of the load; 17695 sensible, 6881 latent90% to 130% of 19316 Btu/h; 17018 sensible, 2299 latentPassUnverifiedunit hp-v24; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forprimary-bed128 cfm128 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forprimary-bath34 cfm34 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forprimary-closet10 cfm10 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forhall24 cfm24 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forbed-2119 cfm119 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forbath-211 cfm11 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forlaundry32 cfm32 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forliving149 cfm149 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forkitchen129 cfm129 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forbed-3114 cfm114 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks forutility24 cfm24 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Each room gets the airflow its Manual J load asks fordining130 cfm130 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1The duct system's pressure loss fits the blower's statichvac0.333 in. w.c. (supply 0.131, return 0.042, filter, register and grille)<= 0.500 in. w.c. the blower delivers its airflow againstPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-w-1810 fpm in 12 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-w-2810 fpm in 9 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-w-3613 fpm in 9 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-kitchen483 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-living558 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-bath-2126 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-laundry367 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-primary-bath390 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-primary-closet115 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-bed-2445 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-hall275 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-primary-bed479 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-e-1607 fpm in 9 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-e-2576 fpm in 7 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-bed-3581 fpm in 6 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-dining486 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-br-utility275 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2021 §M1601.1Duct air velocity stays under the Manual D limithvac-return-1647 fpm in 16 in.<= 700 fpm (return)PassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-w-1R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-w-2R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-w-3R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-kitchenR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-livingR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-bath-2R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-laundryR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-primary-bathR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-primary-closetR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-bed-2R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-hallR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-primary-bedR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-e-1R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-e-2R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-bed-3R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-diningR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-utilityR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-return-1R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.5Ducts, air handlers and filter boxes are sealedhvacevery duct states its sealingsealedPassUnverified
mechanicalInternational Residential Code 2021 §M1501.1Exhaust air discharges outdoors, not into an attic or crawlspacehvac-exh-primary-bathhvac-exh-duct-primary-bath to ext-s, outdoorsan exterior wall, discharging outdoorsPassUnverified
mechanicalInternational Residential Code 2021 §M1501.1Exhaust air discharges outdoors, not into an attic or crawlspacehvac-exh-bath-2hvac-exh-duct-bath-2 to ext-n, outdoorsan exterior wall, discharging outdoorsPassUnverified
mechanicalInternational Residential Code 2021 §M1501.1Exhaust air discharges outdoors, not into an attic or crawlspacehvac-exh-kitchenhvac-exh-duct-kitchen to ext-n, outdoorsan exterior wall, discharging outdoorsPassUnverified
mechanicalInternational Residential Code 2021 §M1505.4.4Bath and kitchen local exhaust meets the minimum rateshvac-exh-primary-bath80 cfm, 45 cfm continuous50 cfm intermittent or 20 cfm continuousPassUnverified
mechanicalInternational Residential Code 2021 §M1505.4.4Bath and kitchen local exhaust meets the minimum rateshvac-exh-bath-280 cfm50 cfm intermittent or 20 cfm continuousPassUnverified
mechanicalInternational Residential Code 2021 §M1505.4.4Bath and kitchen local exhaust meets the minimum rateshvac-exh-kitchen150 cfm100 cfm intermittent or 25 cfm continuousPassUnverified
mechanicalInternational Residential Code 2021 §M1503.6A kitchen exhaust over 400 cfm has makeup airhvac-exh-kitchen150 cfmmakeup air over 400 cfmNot applicableUnverified
mechanicalInternational Residential Code 2021 §M1505.4.3Whole-house ventilation meets 0.01 x floor area + 7.5 x (bedrooms + 1)hvac-ventilation45 cfm continuous44.2 cfm (1% of floor area + 7.5 per occupant)PassUnverified
mechanicalInternational Residential Code 2021 §N1103.3.6Ducts are leakage testedhvac——UncheckedUnverifiedduct leakage is a test of the built system; a design cannot be tested