Three-bedroom ranch

Building ranch-3bed-2bath at revision 166f5b18ca04, checked against model-2018.

These findings are a model check, not a plan review or a stamped design. The mechanical design follows the published ACCA procedure; not ACCA-approved software. No cited rule has been checked against a copy of its adopted code book, and each finding says so.
Drawing sheetsIFC4PDF plan setSchedule
Code profile
model-2018
Passed
258
Failed
0
UncheckedAn input was missing, so the rule could not be judged. An unchecked finding is never counted as a pass.
43
Unverified rulesRules whose citation and threshold have not been checked against a copy of the adopted code book.
96
Rooms
12
Sheets
7

Plan from a briefGenerates a floor plan from the brief, designs the electrical, plumbing and mechanical layers for it, and makes it the active building.

Reference ranch

ElectricalThe optional dwelling load calculation of NEC 220.82: general lighting at 3 VA a square foot, the demand factors of 220.82(B), and heating and cooling at 100 %.

General lighting
4,738 VA over 1579.4 ft²
Small appliance and laundry
3,000 VA and 1,500 VA
Demand load
19,999 VA
HVAC load
3,384 VA
Total load
23,383 VA, 97.4 A at 240.0 V
Panel
panel: 23 of 40 spaces
Leg balance
A 20,601 VA, B 20,255 VA

PlumbingFixture units are tallied from the fixtures in the document. The critical outlet is the one with the least pressure left after elevation and Hazen-Williams friction.

Water supply fixture units
18.5 (6.9 hot, 14.9 cold)
Drainage fixture units
19
Water heater
50 gal tank, 4,500 W; first hour 55 gal against a peak hour of 50 gal
Critical outlet
shower-1: 40.3 psi left, 20 psi required
Pressure budget
60 psi - 11.7 service - 2.5 climb - 5.6 friction over 73 ft = 40.3 psi

MechanicalLoads, equipment and ducts in the manner of Manual J, S and D. The design follows the published ACCA procedure; not ACCA-approved software.

Heating load
17,171 Btu/h
Cooling load
19,316 Btu/h (17,018 sensible, 2,299 latent)
Heat pump
hp-v24, variable: 24,000 Btu/h with a 0 kW strip
Ducts
0.34 in. w.c. available, 260 ft effective length, 0.131 in. per 100 ft
Ventilation
44.2 cfm required, 28.5 cfm infiltration
Design-day drift
heating 0.0 °F, cooling 7.5 °F

Code profileA model code edition, or a jurisdiction's adoption of one. A local amendment has its own rule id and cites the authority that adopted it; like every rule here it is unverified.

House and servicesWalls with their openings cut out, the roof, and the electrical, plumbing and mechanical runs coloured by system. Drag to turn the house, scroll to zoom, or pick a design day to colour the floor by temperature through 24 hours.

Sleeping Room FloorsBath & Laundry Tile FloorsLiving & Hall FloorsKitchen FloorUtility & Service FloorsExterior Walls (X-Ray Cutaway)Window Glazing & FramesDoors & ThresholdsInterior Partitions (X-Ray Cutaway)Countertops & Plumbing/Appliance Fit-OutService & Mechanical EquipmentGable Roof PlanesElectrical Service FeederSmall-Appliance Circuits (20A)Bath, Laundry & Outdoor 20A CircuitsSmoke & CO Alarm Interconnect CircuitGeneral Lighting & Receptacle CircuitsDedicated Appliance & HVAC 240V CircuitsCold Water Supply (PEX)Hot Water Supply (PEX)T&P Relief DischargeSanitary Drain & Waste (DWV)Plumbing Vent Stack SystemHVAC Supply Trunk & Branch DuctsHVAC Return Ductwork & GrilleBath, Kitchen & Whole-House Exhaust Ducts
Footprint
16.3 m by 10.5 m
Meshes
26

Drawing setEach sheet is drawn in whole millimetres from the building document, with its title block, scale and the model-check note. None is permit-ready or stamped.

Sheet
P-101 Three-bedroom ranch: Main floor plumbing plan
Paper and scale
A1 at 1:50
Revision
166f5b18ca04
Open this sheetDXFCAD text
Primary BedroomPrimary BathPrimary ClosetHallBedroom 2Bath 2LaundryLiving RoomKitchenBedroom 3UtilityDining RoomMain shutoff valveWater hammer arrestor at dishwasherWater hammer arrestor at washerThermal expansion tankWater heater cold shutoffTemperature and pressure relief valve1-1/4 in trap for lav-1a1-1/4 in trap for lav-1b1-1/2 in trap for shower-11-1/4 in trap for lav-21-1/2 in trap for tub-21-1/2 in trap for kitchen-sink1-1/2 in trap for dishwasher2 in trap for washerCleanout at the head of the building drainCleanout where the building drain leaves for the sewercold-main-1 1 in PEXcold-main-2 1 in PEXcold-main-3 1 in PEXcold-main-4 1 in PEXcold-main-5 1 in PEXcold-main-6 1 in PEXcold-main-7 1 in PEXcold-main-8 3/4 in PEXcold-main-9 3/4 in PEXcold-main-10 3/4 in PEXcold-main-11 3/4 in PEXcold-lav-1a 1/2 in PEXcold-lav-1b 1/2 in PEXcold-wc-1 3/4 in PEXcold-shower-1 1/2 in PEXcold-lav-2 1/2 in PEXcold-wc-2 3/4 in PEXcold-tub-2 1/2 in PEXcold-kitchen-sink 1/2 in PEXcold-washer 1/2 in PEXcold-hose-bibb-w 3/4 in PEXcold-hose-bibb-e 3/4 in PEXcold-water-heater 1 in PEXhot-heater 1 in PEXhot-main-1 1 in PEXhot-main-2 3/4 in PEXhot-main-3 3/4 in PEXhot-main-4 3/4 in PEXhot-main-5 3/4 in PEXhot-main-6 3/4 in PEXhot-main-7 1/2 in PEXhot-main-8 1/2 in PEXhot-lav-1a 1/2 in PEXhot-lav-1b 1/2 in PEXhot-shower-1 1/2 in PEXhot-lav-2 1/2 in PEXhot-tub-2 1/2 in PEXhot-kitchen-sink 1/2 in PEXhot-dishwasher 1/2 in PEXhot-washer 1/2 in PEXrelief-line 3/4 in CPVCbuilding-drain-1 3 in PVCbuilding-drain-2 3 in PVCbuilding-drain-3 3 in PVCbuilding-drain-4 3 in PVCbuilding-drain-5 3 in PVCbuilding-drain-6 3 in PVCbuilding-drain-7 3 in PVCbuilding-drain-8 3 in PVCdrain-lav-1a 1-1/2 in PVCdrain-lav-1b 1-1/2 in PVCdrain-wc-1 3 in PVCdrain-shower-1 1-1/2 in PVCdrain-lav-2 1-1/2 in PVCdrain-wc-2 3 in PVCdrain-tub-2 1-1/2 in PVCdrain-kitchen-sink 1-1/2 in PVCdrain-dishwasher 1-1/2 in PVCdrain-washer 2 in PVCsystemcold-waterhot-waterrelief-dischargedwvventkindcold-waterhot-waterrelief-dischargedwvventnameCold waterHot waterRelief dischargeDrain, waste and ventVentssourcewater-servicewater-heaterwater-heatersewer-Three-bedroom ranch: Main floor plumbing planDesigned by cre8-app-bim-plumbing 0.1.0 against architecture revision ccb054923a05.WARNING: the architecture has changed since this layer was designed (it is now deca0250f7f6); the layer has to be checked against it again.Drawn from the layer's systems, devices and runs; nothing is added.Model check only: not permit-ready, not stamped.Three-bedroom ranch: Main floor plumbing planNUMBERP-101SCALE1:50UNITSmillimetresSHEETP-101 A1DATE2026-11-01DRAWNCRE8 BIMREV166f5b18ca04REVISION166f5b18ca04CRE8 CAD

Panel schedule

CircuitServesSpacesBreakerLoadCableRunVoltage drop
ckt-sa-1Small appliance 11420 A at 120 V1,500 VA12/2 NM-B162.1 ft6.52 %
ckt-sa-2Small appliance 21920 A at 120 V1,500 VA12/2 NM-B149.4 ft6.01 %
ckt-laundryLaundry1320 A at 120 V1,500 VA12/2 NM-B59.9 ft2.41 %
ckt-bathBathroom receptacles1520 A at 120 V1,500 VA12/2 NM-B88.2 ft3.54 %
ckt-outdoorOutdoor receptacles2220 A at 120 V540 VA12/2 NM-B127.8 ft1.85 %
ckt-alarmsSmoke alarms1815 A at 120 V900 VA14/3 NM-B133.1 ft5.11 %
ckt-general-1General 11220 A at 120 V1,753 VA12/2 NM-B545.7 ft25.65 %
ckt-general-2General 21020 A at 120 V1,780 VA12/2 NM-B442.4 ft21.11 %
ckt-general-3General 32120 A at 120 V738 VA12/2 NM-B114.7 ft2.27 %
ckt-disposalDisposal2020 A at 120 V840 VA12/2 NM-B49.5 ft1.12 %
ckt-dishwasherDishwasher1720 A at 120 V1,200 VA12/2 NM-B47.5 ft1.53 %
ckt-rangeRange1, 340 A at 240 V12,000 VA8/3 NM-B48.6 ft1.55 %
ckt-microwaveMicrowave1620 A at 120 V1,500 VA12/2 NM-B42.5 ft1.71 %
ckt-refrigeratorRefrigerator2320 A at 120 V720 VA12/2 NM-B41.5 ft0.8 %
ckt-dryerClothes dryer2, 430 A at 240 V5,000 VA10/3 NM-B58.0 ft1.22 %
ckt-air-handlerair handler9, 1115 A at 240 V576 VA14/2 NM-B33.6 ft0.21 %
ckt-heat-pumpheat pump outdoor unit6, 820 A at 240 V2,808 VA12/2 NM-B15.9 ft0.3 %
ckt-water-heater50 gal electric5, 725 A at 240 V4,500 VA10/2 NM-B25.2 ft0.48 %
18 rows

Room loads

RoomHeatingCooling, sensibleCooling, latentSolarThe part of the sensible cooling load that comes through the glass.
primary-bed1,807 Btu/h2,352 Btu/h95 Btu/h1,613 Btu/h
primary-bath561 Btu/h443 Btu/h29 Btu/h221 Btu/h
primary-closet161 Btu/h59 Btu/h0 Btu/h0 Btu/h
hall397 Btu/h165 Btu/h14 Btu/h0 Btu/h
bed-21,807 Btu/h2,195 Btu/h95 Btu/h1,480 Btu/h
bath-2190 Btu/h69 Btu/h0 Btu/h0 Btu/h
laundry532 Btu/h357 Btu/h29 Btu/h161 Btu/h
living1,888 Btu/h2,744 Btu/h851 Btu/h1,103 Btu/h
kitchen1,465 Btu/h2,371 Btu/h51 Btu/h645 Btu/h
bed-31,893 Btu/h2,082 Btu/h98 Btu/h1,311 Btu/h
utility402 Btu/h173 Btu/h17 Btu/h0 Btu/h
dining2,164 Btu/h1,695 Btu/h102 Btu/h807 Btu/h
12 rows

Code findingsEvery finding cites its code book, the adopted edition and the section. Hover a rule for its id.

DisciplineSectionThe code book, the edition this profile adopts and the section the rule cites.RuleA paraphrase of the rule's title, never the code text.ElementMeasuredRequiredStatusUnchecked means an input was missing. It is never counted as a pass.Book checkWhether the citation and the threshold have been checked against a copy of the adopted code book.Note
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areaprimary-bed22.2 sq ft12.5 sq ft (8% of 156.4 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areaprimary-bed20.0 sq ft6.3 sq ft (4% of 156.4 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustprimary-bed——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftprimary-bed156.4 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionprimary-bed11 ft 7 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryprimary-bed8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsideprimary-bedwin-bed1-s (Window)one escape opening meeting R310.2PassUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideprimary-bedwin-bed1-s: 10.0 sq ft clear, 48.0 in high, 30.0 in wide5.0 sq ft, 24.0 in high, 20.0 in widePassUnverifiedgrade-floor opening
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorprimary-bedwin-bed1-s: 24.0 in44.0 in or lessPassUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft wideprimary-bed——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areaprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areaprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustprimary-bath4.4 sq ft glazing, 3.7 sq ft openable3.0 sq ft glazing, half openable, or an exhaust fanPassUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryprimary-bath8 ft 0 in6 ft 8 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsideprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft wideprimary-bath——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areaprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areaprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsideprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft wideprimary-closet——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areahall——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areahall——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhausthall——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq fthall——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionhall——Not applicableUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryhall8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsidehall——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widehall——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorhall——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft widehall43.5 in36.0 inPassUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areabed-222.2 sq ft12.5 sq ft (8% of 156.4 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areabed-220.0 sq ft6.3 sq ft (4% of 156.4 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustbed-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftbed-2156.4 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionbed-211 ft 7 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrybed-28 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsidebed-2win-bed2-n (Window)one escape opening meeting R310.2PassUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widebed-2win-bed2-n: 10.0 sq ft clear, 48.0 in high, 30.0 in wide5.0 sq ft, 24.0 in high, 20.0 in widePassUnverifiedgrade-floor opening
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorbed-2win-bed2-n: 24.0 in44.0 in or lessPassUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft widebed-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areabath-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areabath-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustbath-2exhaust fan hvac-exh-bath-23.0 sq ft glazing, half openable, or an exhaust fanPassUnverifiedthe fan's rate is the mechanical design's to check
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftbath-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionbath-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrybath-28 ft 0 in6 ft 8 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsidebath-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widebath-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorbath-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft widebath-2——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor arealaundry——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor arealaundry——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustlaundry——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftlaundry——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionlaundry——Not applicableUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrylaundry8 ft 0 in6 ft 8 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsidelaundry——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widelaundry——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorlaundry——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft widelaundry——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor arealiving24.0 sq ft19.1 sq ft (8% of 239.0 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor arealiving11.6 sq ft9.6 sq ft (4% of 239.0 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustliving——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftliving239.0 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionliving13 ft 8 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryliving8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsideliving——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideliving——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorliving——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft wideliving——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areakitchen19.6 sq ft14.8 sq ft (8% of 184.6 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areakitchen17.5 sq ft7.4 sq ft (4% of 184.6 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustkitchen——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftkitchen——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionkitchen——Not applicableUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrykitchen8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsidekitchen——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widekitchen——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorkitchen——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft widekitchen——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areabed-322.2 sq ft13.6 sq ft (8% of 169.9 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areabed-320.0 sq ft6.8 sq ft (4% of 169.9 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustbed-3——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftbed-3169.9 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionbed-312 ft 7 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrybed-38 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsidebed-3win-bed3-s (Window)one escape opening meeting R310.2PassUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widebed-3win-bed3-s: 10.0 sq ft clear, 48.0 in high, 30.0 in wide5.0 sq ft, 24.0 in high, 20.0 in widePassUnverifiedgrade-floor opening
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorbed-3win-bed3-s: 24.0 in44.0 in or lessPassUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft widebed-3——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areautility——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areautility——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustutility——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftutility——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensionutility——Not applicableUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundryutility——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsideutility——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wideutility——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floorutility——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft wideutility——Not applicableUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have glazing of at least 8% of floor areadining24.8 sq ft14.7 sq ft (8% of 183.5 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.1Habitable rooms have openable area of at least 4% of floor areadining12.0 sq ft7.3 sq ft (4% of 183.5 sq ft)PassUnverified
architectureInternational Residential Code 2018 §R303.3Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaustdining——Not applicableUnverified
architectureInternational Residential Code 2018 §R304.1Habitable rooms other than kitchens have at least 70 sq ftdining183.5 sq ft70.0 sq ftPassUnverified
architectureInternational Residential Code 2018 §R304.2Habitable rooms other than kitchens are at least 7 ft in every plan dimensiondining13 ft 7 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R305.1Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundrydining8 ft 0 in7 ft 0 inPassUnverified
architectureInternational Residential Code 2018 §R310.1Every sleeping room has an operable emergency escape opening to the outsidedining——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.1Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear widedining——Not applicableUnverified
architectureInternational Residential Code 2018 §R310.2.2Escape opening sills are at most 44 in above the floordining——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.6Hallways are at least 3 ft widedining——Not applicableUnverified
architectureInternational Residential Code 2018 §R311.2The dwelling has a side-hinged egress door 32 in clear wide and 78 in clear highranch-3bed-2bathdoor-front: 33.0 in by 79.0 in clear32.0 in by 78.0 in clearPassUnverified
architectureInternational Residential Code 2018 §R408.4Under-floor space has access: 18 by 24 in through the floor, 16 by 24 in by wallcrawlspace18.0 in by 24.0 in18 by 24 inPassUnverified
architectureInternational Residential Code 2018 §R807.1An attic 30 in high has a 22 by 30 in access with 30 in of headroom above itattic22.0 in by 30.0 in, 97.2 in headroom22 by 30 in, 30.0 in headroomPassUnverified
electricalNFPA 70 National Electrical Code 2017 §210.11(A)Enough branch circuits for the calculated general lighting loadranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.11(C)(1)Two or more 20-ampere small-appliance branch circuitsranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.11(C)(2)A 20-ampere laundry branch circuit with no other outletsranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.11(C)(3)A 20-ampere bathroom receptacle branch circuit with no other outletsranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(A)Wall receptacles so no point along the floor line is over 6 ft from oneranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(B)(1)Kitchen, dining and refrigerator receptacles on small-appliance circuitsranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(B)(2)Small-appliance circuits supply no other outletsranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(B)(3)Countertop receptacles fed by two or more small-appliance circuitsranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(C)Countertop receptacles so no point along the wall line is over 24 in from oneranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(D)A receptacle within 3 ft of the outside edge of each bathroom basinranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(E)(1)Outdoor receptacles at the front and back, no higher than 6.5 ft above graderanch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(F)A receptacle where the laundry equipment goesranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(G)Receptacles in garages and unfinished basementsranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.52(H)A receptacle in each hallway 10 ft or longerranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.50(C)An appliance receptacle within 6 ft of the appliance it servesranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.63A service receptacle within 25 ft of heating and cooling equipmentranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.70(A)(1)A switched lighting outlet in each habitable room, kitchen and bathroomranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.70(A)(2)Switched lighting in hallways, stairways, garages and at outdoor entrancesranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.70(A)(3)Lighting in utility and storage spaces and where equipment needs servicingranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.8(A)Ground-fault protection for dwelling receptacles in listed locationsranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.8(D)Ground-fault protection for the dishwasher outletranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.8(F)Ground-fault protection for outdoor outlets on circuits of 50 A or lessranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §210.12(A)Arc-fault protection for circuits supplying living areasranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §422.10An appliance branch circuit rated for the appliance loadranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §422.12Central heating equipment on an individual branch circuitranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §422.13A storage water heater circuit at 125 percent of its ratingranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §110.3(B)Equipment installed and used per its listing and labelingranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §440.32Motor-compressor branch-circuit conductors sized from the nameplateranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §240.4(D)Overcurrent limits for 14, 12 and 10 AWG copper conductorsranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §Table 310.15(B)(16)Conductor ampacity at least the overcurrent device ratingranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §220.82Dwelling load by the optional method within the service ratingranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §230.79(C)A one-family dwelling service of 100 A or moreranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §310.15(B)(7)Dwelling service conductors at 83 percent of the service ratingranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §408.4(A)Every circuit identified in the panel directoryranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalNFPA 70 National Electrical Code 2017 §408.54Overcurrent devices no more than the panel's spacesranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalInternational Residential Code 2018 §R314.3Smoke alarms in and outside each sleeping room and on every storeyranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalInternational Residential Code 2018 §R314.3 item 4Smoke alarms 3 ft or more from a bathroom door with a tub or showerranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalInternational Residential Code 2018 §R314.3.1Smoke alarms kept their distance from cooking appliancesranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalInternational Residential Code 2018 §R314.4Smoke alarms interconnected so one sounds allranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalInternational Residential Code 2018 §R314.6Smoke alarms powered from the building wiring with battery backupranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
electricalInternational Residential Code 2018 §R315.3Carbon monoxide alarms outside sleeping rooms where requiredranch-3bed-2bath——UncheckedUnverifiedthe layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design
plumbingInternational Residential Code 2018 §P2903.3Static pressure at the service is at least 40 psiwater-service60 psi static40 psi at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.3.1Static pressure over 80 psi is cut by a pressure-reducing valvewater-service60 psi static80 psi at most, or a pressure-reducing valvePassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.4Thermal expansion is controlled where the supply cannot push back to the mainexpansion-tankexpansion-tankan expansion controlPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.5Quick-closing valves have water hammer arrestorsdishwasherhammer-arrestor-dishwasheran arrestorPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.5Quick-closing valves have water hammer arrestorswasherhammer-arrestor-washeran arrestorPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.9.1A full-open valve on the water service near where it enterswater-serviceservice-valvea full-open valvePassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.9.2A full-open valve on the cold supply to the water heaterwater-heaterheater-valvea full-open valvePassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7The water service is at least 3/4 incold-service1 in3/4 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-service1 in for 18.5 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-11 in for 16.0 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-21 in for 12.4 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-31 in for 11.4 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-41 in for 9.2 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-51 in for 8.2 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-61 in for 7.7 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-71 in for 6.7 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-83/4 in for 6.2 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-93/4 in for 5.2 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-103/4 in for 4.7 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-main-113/4 in for 2.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-lav-1a1/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-lav-1b1/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-wc-13/4 in for 2.2 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-shower-11/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-lav-21/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-wc-23/4 in for 2.2 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-tub-21/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-kitchen-sink1/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-washer1/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-hose-bibb-w3/4 in for 2.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-hose-bibb-e3/4 in for 2.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthcold-water-heater1 in for 6.9 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-heater1 in for 6.9 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-11 in for 6.9 wsfu1 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-23/4 in for 5.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-33/4 in for 4.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-43/4 in for 3.5 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-53/4 in for 3.0 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-63/4 in for 2.0 wsfu3/4 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-71/2 in for 1.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-main-81/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-lav-1a1/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-lav-1b1/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-shower-11/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-lav-21/2 in for 0.5 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-tub-21/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-kitchen-sink1/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-dishwasher1/2 in for 1.4 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7Mains and branches are sized for their fixture units, pressure and lengthhot-washer1/2 in for 1.0 wsfu1/2 in at leastPassUnverified50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.7The developed length from the meter fits the size column usedcold-water132 ft from the meter200 ft for a 3/4 in meter and 1 in servicePassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.1Each outlet gets its tabulated flow at its tabulated pressurewasher39.0 psi hot8 psi at leastPassUnverifiedthe most remote outlet: 60 psi - 11.7 service - 1.1 climb - 8.2 friction over 82 ft = 39.0 psi; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2903.1Each outlet gets its tabulated flow at its tabulated pressureshower-140.3 psi hot20 psi at leastPassUnverifiedthe least-margin outlet: 60 psi - 11.7 service - 2.5 climb - 5.6 friction over 73 ft = 40.3 psi; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2801.1Hot water outlets are served by a water heaterwater-heater50 gal tank, 55 gal first hour for a 50 gal peak hourthe hot supply starts at the heaterPassUnverifiedtank size is design practice; the IRC sets none; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2804.1A storage water heater has pressure and temperature reliefwater-heaterrelief-valvea temperature and pressure relief valvePassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2804.3Pressure relief opens at no more than 150 psirelief-valve150 psi150 psi at mostPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2804.4Temperature relief opens at no more than 210 F and senses the top 6 in of the tankrelief-valve210 F, sensing 102 mm below the top210 F at most, sensing within 152 mm of the topPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P2804.6.1Relief discharge is full size, never rises and ends no more than 6 in above the floorrelief-line3/4 in ending 150 mm above the floor3/4 in at least, falling, ending within 152 mmPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-10.270 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-20.258 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-30.253 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-40.480 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-50.253 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-60.255 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-70.333 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerbuilding-drain-80.250 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-lav-1a0.267 in/ft1/4 in/ft at least for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-lav-1b0.300 in/ft1/4 in/ft at least for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-wc-10.264 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-shower-10.267 in/ft1/4 in/ft at least for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-lav-20.267 in/ft1/4 in/ft at least for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-wc-20.267 in/ft1/8 in/ft at least for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-tub-20.293 in/ft1/4 in/ft at least for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-kitchen-sink0.250 in/ft1/4 in/ft at least for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-dishwasher0.251 in/ft1/4 in/ft at least for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.3Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and largerdrain-washer0.267 in/ft1/4 in/ft at least for 2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizelav-1a1-1/2 in for 1 dfu1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizelav-1b1-1/2 in for 1 dfu1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizewc-13 in for 3 dfu3 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizeshower-11-1/2 in for 2 dfu1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizelav-21-1/2 in for 1 dfu1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizewc-23 in for 3 dfu3 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizetub-21-1/2 in for 2 dfu1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizekitchen-sink1-1/2 in for 2 dfu1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizedishwasher1-1/2 in for 2 dfu1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.1A fixture branch carries no more drainage fixture units than its sizewasher2 in for 2 dfu1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-13 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-25 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-37 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-48 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-511 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-613 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-715 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.4.2The building drain is sized for its drainage fixture units at its slopebuilding-drain-819 dfu on 3 in at 1/4 in/ft42 dfu at mostPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.2Cleanouts on a horizontal drain are at most 100 ft apartbuilding-drain-131.2 ft longest stretch100 ft at most between cleanoutsPassUnverified2 cleanouts along 32.2 ft of drain; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.2A cleanout at each horizontal change of direction over 45 degreesdwv——Not applicableUnverifiedno horizontal drain turns more than 45 degrees; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3005.2A cleanout within 10 ft of where the building drain meets the sewersewer317 mm to a cleanouta cleanout within 10 ftPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a ventlav-1avent-lav-1aa vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the ventlav-1a1.5 ft6 ft at most for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a ventlav-1bvent-lav-1ba vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the ventlav-1b0.7 ft6 ft at most for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a ventwc-1vent-wc-1a vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the ventwc-11.5 ft12 ft at most for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a ventshower-1vent-shower-1a vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the ventshower-11.5 ft6 ft at most for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a ventlav-2vent-lav-2a vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the ventlav-21.5 ft6 ft at most for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a ventwc-2vent-wc-2a vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the ventwc-21.5 ft12 ft at most for 3 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a venttub-2vent-tub-2a vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the venttub-20.4 ft6 ft at most for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a ventkitchen-sinkvent-kitchen-sinka vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the ventkitchen-sink1.5 ft6 ft at most for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a ventdishwashervent-dishwashera vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the ventdishwasher1.5 ft6 ft at most for 1-1/2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3101.2Every trap seal is protected by a ventwashervent-washera vent on its drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3105.1A trap arm is no longer than its size allows before the ventwasher1.5 ft8 ft at most for 2 inPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3102.1At least one vent extends to the outdoorsventvent-washer ends 600 mm over the roofthrough the roofPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-lav-1a1-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-lav-1b1-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-wc-11-1/2 in1-1/2 in at least for a 3 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-shower-11-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-lav-21-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-wc-21-1/2 in1-1/2 in at least for a 3 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-tub-21-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-kitchen-sink1-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-dishwasher1-1/4 in1-1/4 in at least for a 1-1/2 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3113.1A vent is at least 1-1/4 in and half the diameter of the drain it servesvent-washer1-1/4 in1-1/4 in at least for a 2 in drainPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizelav-1a1-1/4 in1-1/4 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizelav-1b1-1/4 in1-1/4 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizewc-1——Not applicableUnverifiedthe trap is part of the fixture; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizeshower-11-1/2 in1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizelav-21-1/4 in1-1/4 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizewc-2——Not applicableUnverifiedthe trap is part of the fixture; the layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizetub-21-1/2 in1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizekitchen-sink1-1/2 in1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizedishwasher1-1/2 in1-1/2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
plumbingInternational Residential Code 2018 §P3201.7A fixture trap is at least its tabulated sizewasher2 in2 in at leastPassUnverifiedthe layer was designed against an earlier architecture
mechanicalInternational Residential Code 2018 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tablewindow-double-low-eU 0.280U <= 0.300 (fenestration, zone 4A)PassUnverified
mechanicalInternational Residential Code 2018 §N1102.1.2Glazed fenestration meets the climate zone's SHGCwindow-double-low-eSHGC 0.28SHGC <= 0.40 (zone 4A)PassUnverified
mechanicalInternational Residential Code 2018 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tablewall-2x6-r20U 0.060U <= 0.060 (frame wall, zone 4A)PassUnverified
mechanicalInternational Residential Code 2018 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tableceiling-r60U 0.024U <= 0.024 (ceiling, zone 4A)PassUnverified
mechanicalInternational Residential Code 2018 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tablefloor-r19U 0.047U <= 0.047 (floor, zone 4A)PassUnverified
mechanicalInternational Residential Code 2018 §N1102.1.2Envelope assemblies meet the climate zone's U-factor tabledoor-insulated-steelU 0.200U <= 0.300 (fenestration (doors count as fenestration), zone 4A)PassUnverified
mechanicalInternational Residential Code 2018 §N1102.4.1.2Tested air leakage is no more than the zone's ACH50ranch-3bed-2bathno tested or target leakageACH50 <= 3.0UncheckedUnverifiedthe loads assume the zone's maximum
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computableprimary-bedheating 1807 Btu/h, cooling sensible 2352 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computableprimary-bathheating 561 Btu/h, cooling sensible 443 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computableprimary-closetheating 161 Btu/h, cooling sensible 59 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablehallheating 397 Btu/h, cooling sensible 165 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablebed-2heating 1807 Btu/h, cooling sensible 2195 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablebath-2heating 190 Btu/h, cooling sensible 69 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablelaundryheating 532 Btu/h, cooling sensible 357 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablelivingheating 1888 Btu/h, cooling sensible 2744 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablekitchenheating 1465 Btu/h, cooling sensible 2371 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablebed-3heating 1893 Btu/h, cooling sensible 2082 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computableutilityheating 402 Btu/h, cooling sensible 173 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalACCA Manual J 8th edition §Manual JRoom heating and cooling loads are computablediningheating 2164 Btu/h, cooling sensible 1695 Btu/hheating and cooling loads computedPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1401.3Heating equipment is sized to ACCA Manual S on Manual J loadshvac20000 Btu/h at 17 F (20000 heat pump + 0 kW strip)17171 Btu/h heating loadPassUnverifiedunit hp-v24; the layer was designed against an earlier architecture; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1401.3Cooling equipment is sized to ACCA Manual S on Manual J loadshvac24576 Btu/h total at 92 F, 127% of the load; 17695 sensible, 6881 latent90% to 130% of 19316 Btu/h; 17018 sensible, 2299 latentPassUnverifiedunit hp-v24; the layer was designed against an earlier architecture; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forprimary-bed128 cfm128 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forprimary-bath34 cfm34 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forprimary-closet10 cfm10 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forhall24 cfm24 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forbed-2119 cfm119 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forbath-211 cfm11 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forlaundry32 cfm32 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forliving149 cfm149 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forkitchen129 cfm129 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forbed-3114 cfm114 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks forutility24 cfm24 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Each room gets the airflow its Manual J load asks fordining130 cfm130 cfm +/- 10%PassUnverifiedthe larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1The duct system's pressure loss fits the blower's statichvac0.333 in. w.c. (supply 0.131, return 0.042, filter, register and grille)<= 0.500 in. w.c. the blower delivers its airflow againstPassUnverifiedfollows the published ACCA procedure; not ACCA-approved software
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-w-1810 fpm in 12 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-w-2810 fpm in 9 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-w-3613 fpm in 9 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-kitchen483 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-living558 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-bath-2126 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-laundry367 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-primary-bath390 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-primary-closet115 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-bed-2445 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-hall275 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-primary-bed479 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-e-1607 fpm in 9 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-trunk-e-2576 fpm in 7 in.<= 900 fpm (trunk)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-bed-3581 fpm in 6 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-dining486 fpm in 7 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-br-utility275 fpm in 4 in.<= 600 fpm (branch)PassUnverified
mechanicalInternational Residential Code 2018 §M1601.1Duct air velocity stays under the Manual D limithvac-return-1647 fpm in 16 in.<= 700 fpm (return)PassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-w-1R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-w-2R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-w-3R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-kitchenR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-livingR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-bath-2R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-laundryR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-primary-bathR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-primary-closetR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-bed-2R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-hallR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-primary-bedR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-e-1R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-trunk-e-2R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-bed-3R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-diningR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-br-utilityR-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.1Ducts outside conditioned space are insulated to the minimum R-valuehvac-return-1R-8R-6 in the unconditioned spacePassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.5Ducts, air handlers and filter boxes are sealedhvacevery duct states its sealingsealedPassUnverified
mechanicalInternational Residential Code 2018 §M1501.1Exhaust air discharges outdoors, not into an attic or crawlspacehvac-exh-primary-bathhvac-exh-duct-primary-bath to ext-s, outdoorsan exterior wall, discharging outdoorsPassUnverified
mechanicalInternational Residential Code 2018 §M1501.1Exhaust air discharges outdoors, not into an attic or crawlspacehvac-exh-bath-2hvac-exh-duct-bath-2 to ext-n, outdoorsan exterior wall, discharging outdoorsPassUnverified
mechanicalInternational Residential Code 2018 §M1501.1Exhaust air discharges outdoors, not into an attic or crawlspacehvac-exh-kitchenhvac-exh-duct-kitchen to ext-n, outdoorsan exterior wall, discharging outdoorsPassUnverified
mechanicalInternational Residential Code 2018 §M1505.4.4Bath and kitchen local exhaust meets the minimum rateshvac-exh-primary-bath80 cfm, 45 cfm continuous50 cfm intermittent or 20 cfm continuousPassUnverified
mechanicalInternational Residential Code 2018 §M1505.4.4Bath and kitchen local exhaust meets the minimum rateshvac-exh-bath-280 cfm50 cfm intermittent or 20 cfm continuousPassUnverified
mechanicalInternational Residential Code 2018 §M1505.4.4Bath and kitchen local exhaust meets the minimum rateshvac-exh-kitchen150 cfm100 cfm intermittent or 25 cfm continuousPassUnverified
mechanicalInternational Residential Code 2018 §M1503.6A kitchen exhaust over 400 cfm has makeup airhvac-exh-kitchen150 cfmmakeup air over 400 cfmNot applicableUnverified
mechanicalInternational Residential Code 2018 §M1505.4.3Whole-house ventilation meets 0.01 x floor area + 7.5 x (bedrooms + 1)hvac-ventilation45 cfm continuous44.2 cfm (1% of floor area + 7.5 per occupant)PassUnverified
mechanicalInternational Residential Code 2018 §N1103.3.6Ducts are leakage testedhvac——UncheckedUnverifiedduct leakage is a test of the built system; a design cannot be tested
381 rows