1 viewer
Building
Three-bedroom ranch
Building ranch-3bed-2bath at revision 7d9f6a4109a7, checked against model-2021.
- Code profile
- model-2021
- Passed
- 258
- Failed
- 0
- UncheckedAn input was missing, so the rule could not be judged. An unchecked finding is never counted as a pass.
- 43
- Unverified rulesRules whose citation and threshold have not been checked against a copy of the adopted code book.
- 96
- Rooms
- 12
- Sheets
- 7
Plan from a briefGenerates a floor plan from the brief, designs the electrical, plumbing and mechanical layers for it, and makes it the active building.
ElectricalThe optional dwelling load calculation of NEC 220.82: general lighting at 3 VA a square foot, the demand factors of 220.82(B), and heating and cooling at 100 %.
- General lighting
- 4,738 VA over 1579.4 ft²
- Small appliance and laundry
- 3,000 VA and 1,500 VA
- Demand load
- 19,999 VA
- HVAC load
- 3,384 VA
- Total load
- 23,383 VA, 97.4 A at 240.0 V
- Panel
- panel: 23 of 40 spaces
- Leg balance
- A 20,601 VA, B 20,255 VA
PlumbingFixture units are tallied from the fixtures in the document. The critical outlet is the one with the least pressure left after elevation and Hazen-Williams friction.
- Water supply fixture units
- 18.5 (6.9 hot, 14.9 cold)
- Drainage fixture units
- 19
- Water heater
- 50 gal tank, 4,500 W; first hour 55 gal against a peak hour of 50 gal
- Critical outlet
- shower-1: 40.3 psi left, 20 psi required
- Pressure budget
- 60 psi - 11.7 service - 2.5 climb - 5.6 friction over 73 ft = 40.3 psi
MechanicalLoads, equipment and ducts in the manner of Manual J, S and D. The design follows the published ACCA procedure; not ACCA-approved software.
- Heating load
- 17,171 Btu/h
- Cooling load
- 19,316 Btu/h (17,018 sensible, 2,299 latent)
- Heat pump
- hp-v24, variable: 24,000 Btu/h with a 0 kW strip
- Ducts
- 0.34 in. w.c. available, 260 ft effective length, 0.131 in. per 100 ft
- Ventilation
- 44.2 cfm required, 28.5 cfm infiltration
- Design-day drift
- heating 0.0 °F, cooling 7.5 °F
Code profileA model code edition, or a jurisdiction's adoption of one. A local amendment has its own rule id and cites the authority that adopted it; like every rule here it is unverified.
- Jurisdiction
- Model codes as published (no adopting jurisdiction) (ICC 2021 I-Codes and NFPA 70-2020 as published)
- Climate zone
- 4A
House and servicesWalls with their openings cut out, the roof, and the electrical, plumbing and mechanical runs coloured by system. Drag to turn the house, scroll to zoom, or pick a design day to colour the floor by temperature through 24 hours.
- Footprint
- 16.3 m by 10.5 m
- Meshes
- 26
Drawing setEach sheet is drawn in whole millimetres from the building document, with its title block, scale and the model-check note. None is permit-ready or stamped.
- Sheet
- A-101 Three-bedroom ranch: Main floor floor plan
- Paper and scale
- A1 at 1:50
- Revision
- 7d9f6a4109a7
Panel schedule
| Circuit | Serves | Spaces | Breaker | Load | Cable | Run | Voltage drop |
|---|---|---|---|---|---|---|---|
| ckt-sa-1 | Small appliance 1 | 14 | 20 A at 120 V | 1,500 VA | 12/2 NM-B | 162.1 ft | 6.52 % |
| ckt-sa-2 | Small appliance 2 | 19 | 20 A at 120 V | 1,500 VA | 12/2 NM-B | 149.4 ft | 6.01 % |
| ckt-laundry | Laundry | 13 | 20 A at 120 V | 1,500 VA | 12/2 NM-B | 59.9 ft | 2.41 % |
| ckt-bath | Bathroom receptacles | 15 | 20 A at 120 V | 1,500 VA | 12/2 NM-B | 88.2 ft | 3.54 % |
| ckt-outdoor | Outdoor receptacles | 22 | 20 A at 120 V | 540 VA | 12/2 NM-B | 127.8 ft | 1.85 % |
| ckt-alarms | Smoke alarms | 18 | 15 A at 120 V | 900 VA | 14/3 NM-B | 133.1 ft | 5.11 % |
| ckt-general-1 | General 1 | 12 | 20 A at 120 V | 1,753 VA | 12/2 NM-B | 545.7 ft | 25.65 % |
| ckt-general-2 | General 2 | 10 | 20 A at 120 V | 1,780 VA | 12/2 NM-B | 442.4 ft | 21.11 % |
| ckt-general-3 | General 3 | 21 | 20 A at 120 V | 738 VA | 12/2 NM-B | 114.7 ft | 2.27 % |
| ckt-disposal | Disposal | 20 | 20 A at 120 V | 840 VA | 12/2 NM-B | 49.5 ft | 1.12 % |
| ckt-dishwasher | Dishwasher | 17 | 20 A at 120 V | 1,200 VA | 12/2 NM-B | 47.5 ft | 1.53 % |
| ckt-range | Range | 1, 3 | 40 A at 240 V | 12,000 VA | 8/3 NM-B | 48.6 ft | 1.55 % |
| ckt-microwave | Microwave | 16 | 20 A at 120 V | 1,500 VA | 12/2 NM-B | 42.5 ft | 1.71 % |
| ckt-refrigerator | Refrigerator | 23 | 20 A at 120 V | 720 VA | 12/2 NM-B | 41.5 ft | 0.8 % |
| ckt-dryer | Clothes dryer | 2, 4 | 30 A at 240 V | 5,000 VA | 10/3 NM-B | 58.0 ft | 1.22 % |
| ckt-air-handler | air handler | 9, 11 | 15 A at 240 V | 576 VA | 14/2 NM-B | 33.6 ft | 0.21 % |
| ckt-heat-pump | heat pump outdoor unit | 6, 8 | 20 A at 240 V | 2,808 VA | 12/2 NM-B | 15.9 ft | 0.3 % |
| ckt-water-heater | 50 gal electric | 5, 7 | 25 A at 240 V | 4,500 VA | 10/2 NM-B | 25.2 ft | 0.48 % |
Room loads
| Room | Heating | Cooling, sensible | Cooling, latent | SolarThe part of the sensible cooling load that comes through the glass. |
|---|---|---|---|---|
| primary-bed | 1,807 Btu/h | 2,352 Btu/h | 95 Btu/h | 1,613 Btu/h |
| primary-bath | 561 Btu/h | 443 Btu/h | 29 Btu/h | 221 Btu/h |
| primary-closet | 161 Btu/h | 59 Btu/h | 0 Btu/h | 0 Btu/h |
| hall | 397 Btu/h | 165 Btu/h | 14 Btu/h | 0 Btu/h |
| bed-2 | 1,807 Btu/h | 2,195 Btu/h | 95 Btu/h | 1,480 Btu/h |
| bath-2 | 190 Btu/h | 69 Btu/h | 0 Btu/h | 0 Btu/h |
| laundry | 532 Btu/h | 357 Btu/h | 29 Btu/h | 161 Btu/h |
| living | 1,888 Btu/h | 2,744 Btu/h | 851 Btu/h | 1,103 Btu/h |
| kitchen | 1,465 Btu/h | 2,371 Btu/h | 51 Btu/h | 645 Btu/h |
| bed-3 | 1,893 Btu/h | 2,082 Btu/h | 98 Btu/h | 1,311 Btu/h |
| utility | 402 Btu/h | 173 Btu/h | 17 Btu/h | 0 Btu/h |
| dining | 2,164 Btu/h | 1,695 Btu/h | 102 Btu/h | 807 Btu/h |
Code findingsEvery finding cites its code book, the adopted edition and the section. Hover a rule for its id.
| Discipline | SectionThe code book, the edition this profile adopts and the section the rule cites. | RuleA paraphrase of the rule's title, never the code text. | Element | Measured | Required | StatusUnchecked means an input was missing. It is never counted as a pass. | Book checkWhether the citation and the threshold have been checked against a copy of the adopted code book. | Note |
|---|---|---|---|---|---|---|---|---|
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | primary-bed | 22.2 sq ft | 12.5 sq ft (8% of 156.4 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | primary-bed | 20.0 sq ft | 6.3 sq ft (4% of 156.4 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | primary-bed | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | primary-bed | 156.4 sq ft | 70.0 sq ft | Pass | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | primary-bed | 11 ft 7 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | primary-bed | 8 ft 0 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | primary-bed | win-bed1-s (Window) | one escape opening meeting R310.2 | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | primary-bed | win-bed1-s: 10.0 sq ft clear, 48.0 in high, 30.0 in wide | 5.0 sq ft, 24.0 in high, 20.0 in wide | Pass | Unverified | grade-floor opening |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | primary-bed | win-bed1-s: 24.0 in | 44.0 in or less | Pass | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | primary-bed | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | primary-bath | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | primary-bath | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | primary-bath | 4.4 sq ft glazing, 3.7 sq ft openable | 3.0 sq ft glazing, half openable, or an exhaust fan | Pass | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | primary-bath | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | primary-bath | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | primary-bath | 8 ft 0 in | 6 ft 8 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | primary-bath | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | primary-bath | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | primary-bath | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | primary-bath | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | primary-closet | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | hall | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | hall | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | hall | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | hall | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | hall | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | hall | 8 ft 0 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | hall | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | hall | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | hall | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | hall | 43.5 in | 36.0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | bed-2 | 22.2 sq ft | 12.5 sq ft (8% of 156.4 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | bed-2 | 20.0 sq ft | 6.3 sq ft (4% of 156.4 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | bed-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | bed-2 | 156.4 sq ft | 70.0 sq ft | Pass | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | bed-2 | 11 ft 7 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | bed-2 | 8 ft 0 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | bed-2 | win-bed2-n (Window) | one escape opening meeting R310.2 | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | bed-2 | win-bed2-n: 10.0 sq ft clear, 48.0 in high, 30.0 in wide | 5.0 sq ft, 24.0 in high, 20.0 in wide | Pass | Unverified | grade-floor opening |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | bed-2 | win-bed2-n: 24.0 in | 44.0 in or less | Pass | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | bed-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | bath-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | bath-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | bath-2 | exhaust fan hvac-exh-bath-2 | 3.0 sq ft glazing, half openable, or an exhaust fan | Pass | Unverified | the fan's rate is the mechanical design's to check |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | bath-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | bath-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | bath-2 | 8 ft 0 in | 6 ft 8 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | bath-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | bath-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | bath-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | bath-2 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | laundry | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | laundry | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | laundry | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | laundry | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | laundry | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | laundry | 8 ft 0 in | 6 ft 8 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | laundry | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | laundry | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | laundry | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | laundry | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | living | 24.0 sq ft | 19.1 sq ft (8% of 239.0 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | living | 11.6 sq ft | 9.6 sq ft (4% of 239.0 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | living | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | living | 239.0 sq ft | 70.0 sq ft | Pass | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | living | 13 ft 8 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | living | 8 ft 0 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | living | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | living | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | living | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | living | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | kitchen | 19.6 sq ft | 14.8 sq ft (8% of 184.6 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | kitchen | 17.5 sq ft | 7.4 sq ft (4% of 184.6 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | kitchen | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | kitchen | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | kitchen | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | kitchen | 8 ft 0 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | kitchen | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | kitchen | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | kitchen | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | kitchen | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | bed-3 | 22.2 sq ft | 13.6 sq ft (8% of 169.9 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | bed-3 | 20.0 sq ft | 6.8 sq ft (4% of 169.9 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | bed-3 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | bed-3 | 169.9 sq ft | 70.0 sq ft | Pass | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | bed-3 | 12 ft 7 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | bed-3 | 8 ft 0 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | bed-3 | win-bed3-s (Window) | one escape opening meeting R310.2 | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | bed-3 | win-bed3-s: 10.0 sq ft clear, 48.0 in high, 30.0 in wide | 5.0 sq ft, 24.0 in high, 20.0 in wide | Pass | Unverified | grade-floor opening |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | bed-3 | win-bed3-s: 24.0 in | 44.0 in or less | Pass | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | bed-3 | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | utility | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have glazing of at least 8% of floor area | dining | 24.8 sq ft | 14.7 sq ft (8% of 183.5 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.1 | Habitable rooms have openable area of at least 4% of floor area | dining | 12.0 sq ft | 7.3 sq ft (4% of 183.5 sq ft) | Pass | Unverified | |
| architecture | International Residential Code 2021 §R303.3 | Bathrooms have 3 sq ft of glazing, half openable, or a mechanical exhaust | dining | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R304.1 | Habitable rooms other than kitchens have at least 70 sq ft | dining | 183.5 sq ft | 70.0 sq ft | Pass | Unverified | |
| architecture | International Residential Code 2021 §R304.2 | Habitable rooms other than kitchens are at least 7 ft in every plan dimension | dining | 13 ft 7 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R305.1 | Ceilings are at least 7 ft in habitable rooms and halls, 6 ft 8 in in baths and laundry | dining | 8 ft 0 in | 7 ft 0 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R310.1 | Every sleeping room has an operable emergency escape opening to the outside | dining | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.1 | Escape openings give 5.7 sq ft clear (5.0 at grade floor), 24 in clear high, 20 in clear wide | dining | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R310.2.2 | Escape opening sills are at most 44 in above the floor | dining | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.6 | Hallways are at least 3 ft wide | dining | — | — | Not applicable | Unverified | |
| architecture | International Residential Code 2021 §R311.2 | The dwelling has a side-hinged egress door 32 in clear wide and 78 in clear high | ranch-3bed-2bath | door-front: 33.0 in by 79.0 in clear | 32.0 in by 78.0 in clear | Pass | Unverified | |
| architecture | International Residential Code 2021 §R408.4 | Under-floor space has access: 18 by 24 in through the floor, 16 by 24 in by wall | crawlspace | 18.0 in by 24.0 in | 18 by 24 in | Pass | Unverified | |
| architecture | International Residential Code 2021 §R807.1 | An attic 30 in high has a 22 by 30 in access with 30 in of headroom above it | attic | 22.0 in by 30.0 in, 97.2 in headroom | 22 by 30 in, 30.0 in headroom | Pass | Unverified | |
| electrical | NFPA 70 National Electrical Code 2020 §210.11(A) | Enough branch circuits for the calculated general lighting load | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.11(C)(1) | Two or more 20-ampere small-appliance branch circuits | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.11(C)(2) | A 20-ampere laundry branch circuit with no other outlets | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.11(C)(3) | A 20-ampere bathroom receptacle branch circuit with no other outlets | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(A) | Wall receptacles so no point along the floor line is over 6 ft from one | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(B)(1) | Kitchen, dining and refrigerator receptacles on small-appliance circuits | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(B)(2) | Small-appliance circuits supply no other outlets | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(B)(3) | Countertop receptacles fed by two or more small-appliance circuits | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(C) | Countertop receptacles so no point along the wall line is over 24 in from one | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(D) | A receptacle within 3 ft of the outside edge of each bathroom basin | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(E)(1) | Outdoor receptacles at the front and back, no higher than 6.5 ft above grade | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(F) | A receptacle where the laundry equipment goes | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(G) | Receptacles in garages and unfinished basements | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.52(H) | A receptacle in each hallway 10 ft or longer | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.50(C) | An appliance receptacle within 6 ft of the appliance it serves | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.63 | A service receptacle within 25 ft of heating and cooling equipment | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.70(A)(1) | A switched lighting outlet in each habitable room, kitchen and bathroom | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.70(A)(2) | Switched lighting in hallways, stairways, garages and at outdoor entrances | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.70(A)(3) | Lighting in utility and storage spaces and where equipment needs servicing | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.8(A) | Ground-fault protection for dwelling receptacles in listed locations | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.8(D) | Ground-fault protection for the dishwasher outlet | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.8(F) | Ground-fault protection for outdoor outlets on circuits of 50 A or less | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §210.12(A) | Arc-fault protection for circuits supplying living areas | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §422.10 | An appliance branch circuit rated for the appliance load | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §422.12 | Central heating equipment on an individual branch circuit | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §422.13 | A storage water heater circuit at 125 percent of its rating | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §110.3(B) | Equipment installed and used per its listing and labeling | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §440.32 | Motor-compressor branch-circuit conductors sized from the nameplate | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §240.4(D) | Overcurrent limits for 14, 12 and 10 AWG copper conductors | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §Table 310.16 | Conductor ampacity at least the overcurrent device rating | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §220.82 | Dwelling load by the optional method within the service rating | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §230.79(C) | A one-family dwelling service of 100 A or more | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §310.12 | Dwelling service conductors at 83 percent of the service rating | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §408.4(A) | Every circuit identified in the panel directory | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | NFPA 70 National Electrical Code 2020 §408.54 | Overcurrent devices no more than the panel's spaces | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | International Residential Code 2021 §R314.3 | Smoke alarms in and outside each sleeping room and on every storey | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | International Residential Code 2021 §R314.3 item 4 | Smoke alarms 3 ft or more from a bathroom door with a tub or shower | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | International Residential Code 2021 §R314.3.1 | Smoke alarms kept their distance from cooking appliances | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | International Residential Code 2021 §R314.4 | Smoke alarms interconnected so one sounds all | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | International Residential Code 2021 §R314.6 | Smoke alarms powered from the building wiring with battery backup | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| electrical | International Residential Code 2021 §R315.3 | Carbon monoxide alarms outside sleeping rooms where required | ranch-3bed-2bath | — | — | Unchecked | Unverified | the layer was designed against an earlier architecture and has to be designed again; model check, not a plan review or a stamped design |
| plumbing | International Residential Code 2021 §P2903.3 | Static pressure at the service is at least 40 psi | water-service | 60 psi static | 40 psi at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.3.1 | Static pressure over 80 psi is cut by a pressure-reducing valve | water-service | 60 psi static | 80 psi at most, or a pressure-reducing valve | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.4 | Thermal expansion is controlled where the supply cannot push back to the main | expansion-tank | expansion-tank | an expansion control | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.5 | Quick-closing valves have water hammer arrestors | dishwasher | hammer-arrestor-dishwasher | an arrestor | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.5 | Quick-closing valves have water hammer arrestors | washer | hammer-arrestor-washer | an arrestor | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.9.1 | A full-open valve on the water service near where it enters | water-service | service-valve | a full-open valve | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.9.2 | A full-open valve on the cold supply to the water heater | water-heater | heater-valve | a full-open valve | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | The water service is at least 3/4 in | cold-service | 1 in | 3/4 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-service | 1 in for 18.5 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-1 | 1 in for 16.0 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-2 | 1 in for 12.4 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-3 | 1 in for 11.4 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-4 | 1 in for 9.2 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-5 | 1 in for 8.2 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-6 | 1 in for 7.7 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-7 | 1 in for 6.7 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-8 | 3/4 in for 6.2 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-9 | 3/4 in for 5.2 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-10 | 3/4 in for 4.7 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-main-11 | 3/4 in for 2.5 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-lav-1a | 1/2 in for 0.5 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-lav-1b | 1/2 in for 0.5 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-wc-1 | 3/4 in for 2.2 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-shower-1 | 1/2 in for 1.0 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-lav-2 | 1/2 in for 0.5 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-wc-2 | 3/4 in for 2.2 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-tub-2 | 1/2 in for 1.0 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-kitchen-sink | 1/2 in for 1.0 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-washer | 1/2 in for 1.0 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-hose-bibb-w | 3/4 in for 2.5 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-hose-bibb-e | 3/4 in for 2.5 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | cold-water-heater | 1 in for 6.9 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-heater | 1 in for 6.9 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-main-1 | 1 in for 6.9 wsfu | 1 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-main-2 | 3/4 in for 5.5 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-main-3 | 3/4 in for 4.5 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-main-4 | 3/4 in for 3.5 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-main-5 | 3/4 in for 3.0 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-main-6 | 3/4 in for 2.0 wsfu | 3/4 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-main-7 | 1/2 in for 1.5 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-main-8 | 1/2 in for 0.5 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-lav-1a | 1/2 in for 0.5 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-lav-1b | 1/2 in for 0.5 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-shower-1 | 1/2 in for 1.0 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-lav-2 | 1/2 in for 0.5 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-tub-2 | 1/2 in for 1.0 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-kitchen-sink | 1/2 in for 1.0 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-dishwasher | 1/2 in for 1.4 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | Mains and branches are sized for their fixture units, pressure and length | hot-washer | 1/2 in for 1.0 wsfu | 1/2 in at least | Pass | Unverified | 50 to 60 psi band, 150 ft column, 3/4 in meter; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.7 | The developed length from the meter fits the size column used | cold-water | 132 ft from the meter | 200 ft for a 3/4 in meter and 1 in service | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.1 | Each outlet gets its tabulated flow at its tabulated pressure | washer | 39.0 psi hot | 8 psi at least | Pass | Unverified | the most remote outlet: 60 psi - 11.7 service - 1.1 climb - 8.2 friction over 82 ft = 39.0 psi; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2903.1 | Each outlet gets its tabulated flow at its tabulated pressure | shower-1 | 40.3 psi hot | 20 psi at least | Pass | Unverified | the least-margin outlet: 60 psi - 11.7 service - 2.5 climb - 5.6 friction over 73 ft = 40.3 psi; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2801.1 | Hot water outlets are served by a water heater | water-heater | 50 gal tank, 55 gal first hour for a 50 gal peak hour | the hot supply starts at the heater | Pass | Unverified | tank size is design practice; the IRC sets none; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2804.1 | A storage water heater has pressure and temperature relief | water-heater | relief-valve | a temperature and pressure relief valve | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2804.3 | Pressure relief opens at no more than 150 psi | relief-valve | 150 psi | 150 psi at most | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2804.4 | Temperature relief opens at no more than 210 F and senses the top 6 in of the tank | relief-valve | 210 F, sensing 102 mm below the top | 210 F at most, sensing within 152 mm of the top | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P2804.6.1 | Relief discharge is full size, never rises and ends no more than 6 in above the floor | relief-line | 3/4 in ending 150 mm above the floor | 3/4 in at least, falling, ending within 152 mm | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | building-drain-1 | 0.270 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | building-drain-2 | 0.258 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | building-drain-3 | 0.253 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | building-drain-4 | 0.480 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | building-drain-5 | 0.253 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | building-drain-6 | 0.255 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | building-drain-7 | 0.333 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | building-drain-8 | 0.250 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-lav-1a | 0.267 in/ft | 1/4 in/ft at least for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-lav-1b | 0.300 in/ft | 1/4 in/ft at least for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-wc-1 | 0.264 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-shower-1 | 0.267 in/ft | 1/4 in/ft at least for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-lav-2 | 0.267 in/ft | 1/4 in/ft at least for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-wc-2 | 0.267 in/ft | 1/8 in/ft at least for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-tub-2 | 0.293 in/ft | 1/4 in/ft at least for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-kitchen-sink | 0.250 in/ft | 1/4 in/ft at least for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-dishwasher | 0.251 in/ft | 1/4 in/ft at least for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.3 | Horizontal drains fall 1/4 in/ft at 2-1/2 in and smaller, 1/8 in/ft at 3 in and larger | drain-washer | 0.267 in/ft | 1/4 in/ft at least for 2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | lav-1a | 1-1/2 in for 1 dfu | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | lav-1b | 1-1/2 in for 1 dfu | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | wc-1 | 3 in for 3 dfu | 3 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | shower-1 | 1-1/2 in for 2 dfu | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | lav-2 | 1-1/2 in for 1 dfu | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | wc-2 | 3 in for 3 dfu | 3 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | tub-2 | 1-1/2 in for 2 dfu | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | kitchen-sink | 1-1/2 in for 2 dfu | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | dishwasher | 1-1/2 in for 2 dfu | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.1 | A fixture branch carries no more drainage fixture units than its size | washer | 2 in for 2 dfu | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.2 | The building drain is sized for its drainage fixture units at its slope | building-drain-1 | 3 dfu on 3 in at 1/4 in/ft | 42 dfu at most | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.2 | The building drain is sized for its drainage fixture units at its slope | building-drain-2 | 5 dfu on 3 in at 1/4 in/ft | 42 dfu at most | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.2 | The building drain is sized for its drainage fixture units at its slope | building-drain-3 | 7 dfu on 3 in at 1/4 in/ft | 42 dfu at most | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.2 | The building drain is sized for its drainage fixture units at its slope | building-drain-4 | 8 dfu on 3 in at 1/4 in/ft | 42 dfu at most | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.2 | The building drain is sized for its drainage fixture units at its slope | building-drain-5 | 11 dfu on 3 in at 1/4 in/ft | 42 dfu at most | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.2 | The building drain is sized for its drainage fixture units at its slope | building-drain-6 | 13 dfu on 3 in at 1/4 in/ft | 42 dfu at most | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.2 | The building drain is sized for its drainage fixture units at its slope | building-drain-7 | 15 dfu on 3 in at 1/4 in/ft | 42 dfu at most | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.4.2 | The building drain is sized for its drainage fixture units at its slope | building-drain-8 | 19 dfu on 3 in at 1/4 in/ft | 42 dfu at most | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.2 | Cleanouts on a horizontal drain are at most 100 ft apart | building-drain-1 | 31.2 ft longest stretch | 100 ft at most between cleanouts | Pass | Unverified | 2 cleanouts along 32.2 ft of drain; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.2 | A cleanout at each horizontal change of direction over 45 degrees | dwv | — | — | Not applicable | Unverified | no horizontal drain turns more than 45 degrees; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3005.2 | A cleanout within 10 ft of where the building drain meets the sewer | sewer | 317 mm to a cleanout | a cleanout within 10 ft | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | lav-1a | vent-lav-1a | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | lav-1a | 1.5 ft | 6 ft at most for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | lav-1b | vent-lav-1b | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | lav-1b | 0.7 ft | 6 ft at most for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | wc-1 | vent-wc-1 | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | wc-1 | 1.5 ft | 12 ft at most for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | shower-1 | vent-shower-1 | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | shower-1 | 1.5 ft | 6 ft at most for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | lav-2 | vent-lav-2 | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | lav-2 | 1.5 ft | 6 ft at most for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | wc-2 | vent-wc-2 | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | wc-2 | 1.5 ft | 12 ft at most for 3 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | tub-2 | vent-tub-2 | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | tub-2 | 0.4 ft | 6 ft at most for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | kitchen-sink | vent-kitchen-sink | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | kitchen-sink | 1.5 ft | 6 ft at most for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | dishwasher | vent-dishwasher | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | dishwasher | 1.5 ft | 6 ft at most for 1-1/2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3101.2 | Every trap seal is protected by a vent | washer | vent-washer | a vent on its drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3105.1 | A trap arm is no longer than its size allows before the vent | washer | 1.5 ft | 8 ft at most for 2 in | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3102.1 | At least one vent extends to the outdoors | vent | vent-washer ends 600 mm over the roof | through the roof | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-lav-1a | 1-1/4 in | 1-1/4 in at least for a 1-1/2 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-lav-1b | 1-1/4 in | 1-1/4 in at least for a 1-1/2 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-wc-1 | 1-1/2 in | 1-1/2 in at least for a 3 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-shower-1 | 1-1/4 in | 1-1/4 in at least for a 1-1/2 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-lav-2 | 1-1/4 in | 1-1/4 in at least for a 1-1/2 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-wc-2 | 1-1/2 in | 1-1/2 in at least for a 3 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-tub-2 | 1-1/4 in | 1-1/4 in at least for a 1-1/2 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-kitchen-sink | 1-1/4 in | 1-1/4 in at least for a 1-1/2 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-dishwasher | 1-1/4 in | 1-1/4 in at least for a 1-1/2 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3113.1 | A vent is at least 1-1/4 in and half the diameter of the drain it serves | vent-washer | 1-1/4 in | 1-1/4 in at least for a 2 in drain | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | lav-1a | 1-1/4 in | 1-1/4 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | lav-1b | 1-1/4 in | 1-1/4 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | wc-1 | — | — | Not applicable | Unverified | the trap is part of the fixture; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | shower-1 | 1-1/2 in | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | lav-2 | 1-1/4 in | 1-1/4 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | wc-2 | — | — | Not applicable | Unverified | the trap is part of the fixture; the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | tub-2 | 1-1/2 in | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | kitchen-sink | 1-1/2 in | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | dishwasher | 1-1/2 in | 1-1/2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| plumbing | International Residential Code 2021 §P3201.7 | A fixture trap is at least its tabulated size | washer | 2 in | 2 in at least | Pass | Unverified | the layer was designed against an earlier architecture |
| mechanical | International Residential Code 2021 §N1102.1.2 | Envelope assemblies meet the climate zone's U-factor table | window-double-low-e | U 0.280 | U <= 0.300 (fenestration, zone 4A) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1102.1.2 | Glazed fenestration meets the climate zone's SHGC | window-double-low-e | SHGC 0.28 | SHGC <= 0.40 (zone 4A) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1102.1.2 | Envelope assemblies meet the climate zone's U-factor table | wall-2x6-r20 | U 0.060 | U <= 0.060 (frame wall, zone 4A) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1102.1.2 | Envelope assemblies meet the climate zone's U-factor table | ceiling-r60 | U 0.024 | U <= 0.024 (ceiling, zone 4A) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1102.1.2 | Envelope assemblies meet the climate zone's U-factor table | floor-r19 | U 0.047 | U <= 0.047 (floor, zone 4A) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1102.1.2 | Envelope assemblies meet the climate zone's U-factor table | door-insulated-steel | U 0.200 | U <= 0.300 (fenestration (doors count as fenestration), zone 4A) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1102.4.1.2 | Tested air leakage is no more than the zone's ACH50 | ranch-3bed-2bath | no tested or target leakage | ACH50 <= 3.0 | Unchecked | Unverified | the loads assume the zone's maximum |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | primary-bed | heating 1807 Btu/h, cooling sensible 2352 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | primary-bath | heating 561 Btu/h, cooling sensible 443 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | primary-closet | heating 161 Btu/h, cooling sensible 59 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | hall | heating 397 Btu/h, cooling sensible 165 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | bed-2 | heating 1807 Btu/h, cooling sensible 2195 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | bath-2 | heating 190 Btu/h, cooling sensible 69 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | laundry | heating 532 Btu/h, cooling sensible 357 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | living | heating 1888 Btu/h, cooling sensible 2744 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | kitchen | heating 1465 Btu/h, cooling sensible 2371 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | bed-3 | heating 1893 Btu/h, cooling sensible 2082 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | utility | heating 402 Btu/h, cooling sensible 173 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | ACCA Manual J 8th edition §Manual J | Room heating and cooling loads are computable | dining | heating 2164 Btu/h, cooling sensible 1695 Btu/h | heating and cooling loads computed | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1401.3 | Heating equipment is sized to ACCA Manual S on Manual J loads | hvac | 20000 Btu/h at 17 F (20000 heat pump + 0 kW strip) | 17171 Btu/h heating load | Pass | Unverified | unit hp-v24; the layer was designed against an earlier architecture; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1401.3 | Cooling equipment is sized to ACCA Manual S on Manual J loads | hvac | 24576 Btu/h total at 92 F, 127% of the load; 17695 sensible, 6881 latent | 90% to 130% of 19316 Btu/h; 17018 sensible, 2299 latent | Pass | Unverified | unit hp-v24; the layer was designed against an earlier architecture; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | primary-bed | 128 cfm | 128 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | primary-bath | 34 cfm | 34 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | primary-closet | 10 cfm | 10 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | hall | 24 cfm | 24 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | bed-2 | 119 cfm | 119 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | bath-2 | 11 cfm | 11 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | laundry | 32 cfm | 32 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | living | 149 cfm | 149 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | kitchen | 129 cfm | 129 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | bed-3 | 114 cfm | 114 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | utility | 24 cfm | 24 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Each room gets the airflow its Manual J load asks for | dining | 130 cfm | 130 cfm +/- 10% | Pass | Unverified | the larger of the room's heating and cooling shares; follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | The duct system's pressure loss fits the blower's static | hvac | 0.333 in. w.c. (supply 0.131, return 0.042, filter, register and grille) | <= 0.500 in. w.c. the blower delivers its airflow against | Pass | Unverified | follows the published ACCA procedure; not ACCA-approved software |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-trunk-w-1 | 810 fpm in 12 in. | <= 900 fpm (trunk) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-trunk-w-2 | 810 fpm in 9 in. | <= 900 fpm (trunk) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-trunk-w-3 | 613 fpm in 9 in. | <= 900 fpm (trunk) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-kitchen | 483 fpm in 7 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-living | 558 fpm in 7 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-bath-2 | 126 fpm in 4 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-laundry | 367 fpm in 4 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-primary-bath | 390 fpm in 4 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-primary-closet | 115 fpm in 4 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-bed-2 | 445 fpm in 7 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-hall | 275 fpm in 4 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-primary-bed | 479 fpm in 7 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-trunk-e-1 | 607 fpm in 9 in. | <= 900 fpm (trunk) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-trunk-e-2 | 576 fpm in 7 in. | <= 900 fpm (trunk) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-bed-3 | 581 fpm in 6 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-dining | 486 fpm in 7 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-br-utility | 275 fpm in 4 in. | <= 600 fpm (branch) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1601.1 | Duct air velocity stays under the Manual D limit | hvac-return-1 | 647 fpm in 16 in. | <= 700 fpm (return) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-trunk-w-1 | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-trunk-w-2 | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-trunk-w-3 | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-kitchen | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-living | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-bath-2 | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-laundry | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-primary-bath | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-primary-closet | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-bed-2 | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-hall | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-primary-bed | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-trunk-e-1 | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-trunk-e-2 | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-bed-3 | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-dining | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-br-utility | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.1 | Ducts outside conditioned space are insulated to the minimum R-value | hvac-return-1 | R-8 | R-6 in the unconditioned space | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.5 | Ducts, air handlers and filter boxes are sealed | hvac | every duct states its sealing | sealed | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1501.1 | Exhaust air discharges outdoors, not into an attic or crawlspace | hvac-exh-primary-bath | hvac-exh-duct-primary-bath to ext-s, outdoors | an exterior wall, discharging outdoors | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1501.1 | Exhaust air discharges outdoors, not into an attic or crawlspace | hvac-exh-bath-2 | hvac-exh-duct-bath-2 to ext-n, outdoors | an exterior wall, discharging outdoors | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1501.1 | Exhaust air discharges outdoors, not into an attic or crawlspace | hvac-exh-kitchen | hvac-exh-duct-kitchen to ext-n, outdoors | an exterior wall, discharging outdoors | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1505.4.4 | Bath and kitchen local exhaust meets the minimum rates | hvac-exh-primary-bath | 80 cfm, 45 cfm continuous | 50 cfm intermittent or 20 cfm continuous | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1505.4.4 | Bath and kitchen local exhaust meets the minimum rates | hvac-exh-bath-2 | 80 cfm | 50 cfm intermittent or 20 cfm continuous | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1505.4.4 | Bath and kitchen local exhaust meets the minimum rates | hvac-exh-kitchen | 150 cfm | 100 cfm intermittent or 25 cfm continuous | Pass | Unverified | |
| mechanical | International Residential Code 2021 §M1503.6 | A kitchen exhaust over 400 cfm has makeup air | hvac-exh-kitchen | 150 cfm | makeup air over 400 cfm | Not applicable | Unverified | |
| mechanical | International Residential Code 2021 §M1505.4.3 | Whole-house ventilation meets 0.01 x floor area + 7.5 x (bedrooms + 1) | hvac-ventilation | 45 cfm continuous | 44.2 cfm (1% of floor area + 7.5 per occupant) | Pass | Unverified | |
| mechanical | International Residential Code 2021 §N1103.3.6 | Ducts are leakage tested | hvac | — | — | Unchecked | Unverified | duct leakage is a test of the built system; a design cannot be tested |