Skip to content
1 viewer
Power
Fission · a design

Fission plant

A planning estimate from monthly means and the spread of days inside a month.

Figures are planning estimates. They are not measurements, interconnection studies or engineering advice, and nothing here is sent to any plant or grid. How far to trust them is on the backtest.
The backtest
Rated
2,200 MW
A year
18,442 GWh
Capacity factor
95.7%
A design, not a plant

The site

The plant

Reactors
2 x 3,400 MW of heat, Pressurized water reactor
Steam
284 C at 6.9 MPa
Net in the warmest month
2,200 MW
Net in the coldest month
2,355 MW
Heat to the grid
33.7%
At power
91.7% of the year
Each core
3.51 m across and tall
Heavy metal in the cores
179 t
Replaced each refuelling
38.2%
Fuel loaded a year
45.5 t at 4.5% U-235
Fissioned a year
2,391 kg
Natural uranium a year
420 t
Separative work a year
313 thousand SWU
Heat thrown away
4,496 MW at full power in summer
Cooling water
1.47 m3/s evaporated from the towers, 127 thousand m3 a day
Decay heat, one unit
34.9 MW after an hour, 15.5 MW after a day, 4.8 MW after thirty days

Through the year

Energy by month, GWh.
05001,0001,5002,000Jan: 1,607 GWhJanFeb: 1,452 GWhFebMar: 1,607 GWhMarApr: 1,532 GWhAprMay: 1,545 GWhMayJun: 1,465 GWhJunJul: 1,502 GWhJulAug: 1,508 GWhAugSep: 1,483 GWhSepOct: 1,576 GWhOctNov: 1,556 GWhNovDec: 1,607 GWhDec
MonthAir CCondenser CHeat to the generatorNet at full powerEnergy
Jan-2.02536.3%2,355 MW1,607 GWh
Feb0.02536.3%2,355 MW1,452 GWh
Mar6.02536.3%2,355 MW1,607 GWh
Apr12.02935.7%2,319 MW1,532 GWh
May18.03534.9%2,264 MW1,545 GWh
Jun23.04034.2%2,219 MW1,465 GWh
Jul25.04233.9%2,200 MW1,502 GWh
Aug24.04134.0%2,210 MW1,508 GWh
Sep20.03734.6%2,246 MW1,483 GWh
Oct13.03035.6%2,310 MW1,576 GWh
Nov6.02536.3%2,355 MW1,556 GWh
Dec0.02536.3%2,355 MW1,607 GWh
12 rows

In 3D

To scale: 3.5 m cores. The containments, twelve cores across, the turbine halls and towers sized by the heat they shed are drawn by rule, not sized. Lift layers raises the containments off the cores. 3D starts when Virtual's renderer loads.

What the model leaves out

  • There is no neutronics. Criticality, control, the flux shape and every safety system are outside the model, and nothing here says a reactor of these figures could be licensed.
  • The steam cycle is one share of the Carnot limit, the same for every plant. Reheat, feedwater heating and the turbine's own design are not worked through.
  • The heat sink is the month's air temperature plus a fixed margin. A deep lake or a cold sea runs cooler than the air in summer.
  • Refuelling is spread evenly over the year. A real unit is down for about a month every eighteen or twenty-four, and a year of trouble is not in the model.
  • Units of unlike size are sized alike, at their mean.
  • Spent fuel is counted in tonnes discharged. Its storage and disposal are not modelled.