Skip to content
1 viewer
Power
Wind · OH · being built

Firelands Wind

A planning estimate from monthly means and the spread of days inside a month.

Figures are planning estimates. They are not measurements, interconnection studies or engineering advice, and nothing here is sent to any plant or grid. How far to trust them is on the backtest.
The backtest
Rated
296 MW
A year
1,049 GWh
Capacity factor
40.5%
Being built: no year reported yet

Before it reports

Owner
Firelands Wind, LLC
Where
Huron County, OH
Nameplate
297 MW in 1 generator
Stage
Under construction, half built or less
Planned start
May 2027
Model, a whole year
1,049 GWh
The model was tested on 7 built plants of this kind. Its largest misses either way put this plant's year between 754.0 GWh and 1,448 GWh. This is not a test: the figure is written down so it can be checked against form EIA-923 once the plant has reported 2028 whole.
Assumed, because the inventory does not say
  • Neither the inventory nor the turbine database names a turbine: taken as 3400 kW on a 140 m rotor at 105 m, the median of the 2447 turbines on land the U.S. Wind Turbine Database dates 2024 or later.
Capacity, position, stage and start
EIA-860M inventory of planned generators for September 2026, plant 68186
Climate
NASA POWER's monthly climatology at 41.2103, -82.7791
Read
2026-11-11

The site

The plant

Turbines
87
Wind at the record's height
6.71 m/s at 50 m
Before losses
47.6%
Lost to wakes
9.7%
Fit to run
96.0%
Ground the farm spreads over
4,775 ha
TurbinesRotor mHub mW per m2 sweptWind at hub m/sRated wind m/sCapacity factorA year
87 x 3,400 kW140.0105.02217.459.540.5%1,049 GWh
1 row

Through the year

Energy by month, GWh.
050100150Jan: 112.1 GWhJanFeb: 97.7 GWhFebMar: 103.9 GWhMarApr: 101.2 GWhAprMay: 83.9 GWhMayJun: 68.4 GWhJunJul: 56.8 GWhJulAug: 55.3 GWhAugSep: 67.6 GWhSepOct: 95.6 GWhOctNov: 100.7 GWhNovDec: 106.0 GWhDec
MonthWind m/sAir kg/m3Before lossesEnergy
Jan7.961.26259.9%112.1 GWh
Feb7.681.25857.8%97.7 GWh
Mar7.441.23555.6%103.9 GWh
Apr7.541.20655.9%101.2 GWh
May6.371.18044.8%83.9 GWh
Jun5.751.16137.8%68.4 GWh
Jul5.131.15030.4%56.8 GWh
Aug5.061.15329.6%55.3 GWh
Sep5.701.16737.3%67.6 GWh
Oct6.991.19651.1%95.6 GWh
Nov7.471.22555.6%100.7 GWh
Dec7.551.24956.7%106.0 GWh
12 rows

In 3D

To scale: 140 m rotors on 105 m hubs, four diameters apart across the wind and seven along it. Nacelles are drawn by rule. 6 of 87 turbines drawn. 3D starts when Virtual's renderer loads.

What the model leaves out

  • The wind is one monthly mean speed with a Weibull spread. Direction, gusts, the daily cycle and terrain are not in it.
  • The power curve is a cube to rated power at one power coefficient. A real curve rounds off below rated wind.
  • Wakes are a share of output that grows with the turbine count, not a layout worked through.
  • Icing, curtailment by the grid operator and noise or wildlife shutdowns are not counted.