1 viewer
Solar · TX · being built
Swenson Solar
A planning estimate from monthly means and the spread of days inside a month.
- Rated
- 600 MW
- A year
- 1,495 GWh
- Capacity factor
- 28.4%
Before it reports
- Owner
- Swenson Solar LLC
- Where
- Stonewall County, TX
- Nameplate
- 600 MW in 1 generator
- Stage
- Under construction, half built or less
- Planned start
- Nov 2026
- Model, a whole year
- 1,495 GWh
- The inventory gives no array layout: taken as single-axis trackers, which most plants of this size are now built on.
- The inventory gives the inverter rating only: the modules are taken at 1.3 times it, about the utility-scale median.
- Crystalline silicon modules.
- Capacity, position, stage and start
- EIA-860M inventory of planned generators for September 2026, plant 70135
- Climate
- NASA POWER's monthly climatology at 32.9854, -100.0292
- Read
- 2026-11-11
The site
The plant
- Inverters
- 600 MW
- Modules
- 780 MW, Crystalline silicon
- Mount
- Single-axis trackers, north-south
- Light on level ground
- 1,922 kWh/m2 a year
- Light on the modules
- 2,522 kWh/m2 a year
- Yield
- 1,917 kWh a year per kW of modules
- Performance ratio
- 76.0%
- Lost at the inverter limit
- 0.0%
- Module area
- 380.5 ha
- Land at this ground cover
- 1,087.1 ha
- Losses taken
- 14.0%
Through the year
| Month | Clearness | Dull to clear day, kWh/m2 | Diffuse | On the modules kWh/m2 a day | Cell C | Clipped | Energy |
|---|---|---|---|---|---|---|---|
| Jan | 0.61 | 1.9 to 4.2 | 29.4% | 4.74 | 26 | 0.0% | 92.6 GWh |
| Feb | 0.60 | 2.1 to 5.2 | 36.0% | 5.38 | 30 | 0.0% | 94.3 GWh |
| Mar | 0.62 | 3.0 to 6.6 | 33.6% | 6.86 | 38 | 0.0% | 129.5 GWh |
| Apr | 0.64 | 3.9 to 7.9 | 31.9% | 8.33 | 45 | 0.0% | 148.4 GWh |
| May | 0.61 | 3.8 to 8.6 | 34.2% | 8.59 | 50 | 0.0% | 155.3 GWh |
| Jun | 0.65 | 4.6 to 9.1 | 31.2% | 9.48 | 55 | 0.1% | 162.3 GWh |
| Jul | 0.63 | 4.2 to 8.8 | 32.5% | 9.05 | 57 | 0.0% | 159.3 GWh |
| Aug | 0.62 | 3.8 to 8.1 | 33.1% | 8.35 | 56 | 0.0% | 147.4 GWh |
| Sep | 0.60 | 2.9 to 6.9 | 35.9% | 6.93 | 49 | 0.0% | 121.3 GWh |
| Oct | 0.61 | 2.5 to 5.6 | 33.9% | 5.95 | 41 | 0.0% | 110.7 GWh |
| Nov | 0.61 | 2.0 to 4.4 | 29.6% | 4.95 | 33 | 0.0% | 91.5 GWh |
| Dec | 0.59 | 1.6 to 3.9 | 31.4% | 4.24 | 26 | 0.0% | 82.7 GWh |
In 3D
To scale: 9 tracker rows 2.3 m wide, 6.6 m apart for a ground cover of 0.35, shown turned 35 degrees to the afternoon sun, on a 60 by 40 m patch of the 1087 ha site. 3D starts when Virtual's renderer loads.
What the model leaves out
- Each month is five kinds of day, from its dullest fifth to its clearest, at one air temperature. A day's light keeps a smooth shape: no cloud passes at noon, so clipping still reads a little low.
- Rows do not shade each other, and trackers do not backtrack.
- The sky's diffuse light is taken as even across the sky, which reads a little low for a tilted array under clear sky.
- Soiling, wiring, mismatch, ageing and outages are one share of output, the same in every month.
- Land is module area over ground cover. Roads, setbacks, the substation and unbuildable ground are extra.