1 viewer
Rocket engine
Electric pump, RP-1 kerosene and Liquid oxygenFigures are the model's, including for a published engine.
Equilibrium chemistry, then the cycle closed through its pumps, turbine and cooling jacket.
- Verdict
- Holds every check it can decide
- Vacuum thrust
- 26.97 kN
- Vacuum impulse
- 312.8 s
- Engine mass
- 32.54 kg
Design an engine
Figures
- Vacuum thrust
- 26.97 kN
- Vacuum impulse
- 312.8 s
- Sea-level thrust
- 24.9 kN
- Sea-level impulse
- 288.7 s
- Engine mass
- 32.54 kg
- Thrust to weight, sea level
- 78
- Propellant flow
- 8.794 kg/s
- Dumped overboard
- 0 kg/s
- Chamber gas
- 3,694 K
- Chamber mixture
- 2.4 O/F
- Exit pressure
- 0.864 bar
- Length
- 0.443 m
- Exit diameter
- 0.161 m
Section
SolidEach part is spun from its own section: the chamber liner and jacket from the designed wall, the bell to the designed exit, the skirt where the model puts one. Parts drawn grey-blue on the sheet and named envelope here are placed by rule, and their mass means nothing.
17760 triangles, shaded from the parts' own normals. 3D starts when Virtual's renderer loads.
| Fits | Part | Note |
|---|---|---|
| Fits | Turbopump beside the chamber | the pumps end 301 mm above the exit plane |
DrawingThe sheet's balloons and the stage's labels name the same parts.
Pumps
| Pump | kg/s | Rise, bar | kW | rpm | Stages | Tip, m/s | Impeller, mm |
|---|---|---|---|---|---|---|---|
| Fuel | 2.59 | 162 | 72 | 50,000 | 1 | 191 | 72.9 |
| Oxidizer | 6.21 | 141 | 107 | 50,000 | 1 | 150 | 57.3 |
Cooling
- Throat flux
- 34 MW/m²
- Wall
- 800 K
- Heat taken
- 0.957 MW
- Coolant flow
- 2.59 kg/s
- Coolant out
- 474 K
- Coolant limit
- 600 K
- Film share
- 1.2%
- Channels
- 93, 0.8 × 0.42 mm
- Coolant speed
- 102 m/s
- Jacket drop
- 21.3 bar
Mass
| Part | kg | Share |
|---|---|---|
| Chamber | 2.99 | 9.2% |
| Injector | 0.706 | 2.2% |
| Nozzle | 1.58 | 4.8% |
| Plumbing | 8.11 | 24.9% |
| Electric drive | 19.2 | 58.8% |
| Engine | 32.5 | 100.0% |
Checks
| Verdict | Check | Note |
|---|---|---|
| pass | Flow stays attached | exit 0.86 bar against 1.01 bar ambient, ratio 0.85; Summerfield separates below 0.4 |
| pass | Coolant stays below its limit | RP-1 kerosene leaves the jacket at 474 K, limit 600 K |
| pass | Film cooling | 1.2% of the fuel runs along the wall because the jacket alone would pass its limit |
| pass | Channels can be made | 93 channels 0.4 mm deep at the throat, aspect 0.5, coolant 102 m/s |
| pass | Jacket pressure drop | 21 bar, 18% of the chamber |
What this model assumesConstants the rocket model holds for every design.
| Assumed | Value |
|---|---|
| Pump efficiency | 0.72 |
| Open-cycle turbine efficiency | 0.62 |
| Staged turbine efficiency | 0.8 |
| Turbine exit, bar | 2.5 |
| Suction specific speed | 12 |
| Wall limit, K | 800 |
| Fastest shaft, rpm | 50000 |
| Kerosene carbon skin, share of heat passed | 0.55 |
| Jacket, most of the chamber pressure | 0.35 |
| Film share that cuts wall heat by e | 0.04 |
| Film impulse kept | 0.5 |
| Expander jacket ends at area ratio | 12 |
| Battery, MJ per kg | 0.72 |
| Electric drive efficiency | 0.88 |