1 viewer
Rocket engine
Gas generator, Liquid hydrogen and Liquid oxygenFigures are the model's, including for a published engine.
Equilibrium chemistry, then the cycle closed through its pumps, turbine and cooling jacket.
- Verdict
- Holds every check it can decide
- Vacuum thrust
- 1359 kN
- Vacuum impulse
- 427.2 s
- Engine mass
- 1953 kg
Design an engine
Figures
- Vacuum thrust
- 1359 kN
- Vacuum impulse
- 427.2 s
- Engine mass
- 1953 kg
- Thrust to weight, vacuum
- 71
- Propellant flow
- 324.4 kg/s
- Dumped overboard
- 6.71 kg/s
- Chamber gas
- 3,616 K
- Chamber mixture
- 6.53 O/F
- Exit pressure
- 0.166 bar
- Length
- 3.13 m
- Exit diameter
- 2.12 m
Section
SolidEach part is spun from its own section: the chamber liner and jacket from the designed wall, the bell to the designed exit, the skirt where the model puts one. Parts drawn grey-blue on the sheet and named envelope here are placed by rule, and their mass means nothing.
17980 triangles, shaded from the parts' own normals. 3D starts when Virtual's renderer loads.
| Fits | Part | Note |
|---|---|---|
| Fits | Turbopump beside the chamber | the pumps end 2504 mm above the exit plane |
DrawingThe sheet's balloons and the stage's labels name the same parts.
Pumps
| Pump | kg/s | Rise, bar | kW | rpm | Stages | Tip, m/s | Impeller, mm |
|---|---|---|---|---|---|---|---|
| Fuel | 45.7 | 160 | 14,302 | 50,000 | 2 | 453 | 173 |
| Oxidizer | 279 | 138 | 4,673 | 11,170 | 1 | 148 | 253 |
Turbines
| Drive gas | kg/s | Inlet, K | Inlet, bar | Ratio | kW |
|---|---|---|---|---|---|
| Burnt at 0.917 O/F | 6.71 | 900 | 117 | 46.9 | 18,975 |
Cooling
- Throat flux
- 72.5 MW/m²
- Wall
- 800 K
- Heat taken
- 55.7 MW
- Coolant flow
- 42.2 kg/s
- Coolant out
- 113 K
- Coolant limit
- None set
- Film share
- 0.0%
- Channels
- 230, 2.2 × 6.3 mm
- Coolant speed
- 267 m/s
- Jacket drop
- 21.8 bar
Mass
| Part | kg | Share |
|---|---|---|
| Chamber | 204 | 10.5% |
| Injector | 163 | 8.3% |
| Nozzle | 527 | 27.0% |
| Turbomachinery | 547 | 28.0% |
| Plumbing | 513 | 26.2% |
| Engine | 1950 | 100.0% |
Checks
| Verdict | Check | Note |
|---|---|---|
| pass | Coolant stays below its limit | Liquid hydrogen leaves the jacket at 113 K with no chemical limit |
| pass | Channels can be made | 230 channels 6.3 mm deep at the throat, aspect 2.8, coolant 267 m/s |
| pass | Jacket pressure drop | 22 bar, 19% of the chamber |
| pass | Preburner pressure | 117 bar at the hottest turbine inlet |
What this model assumesConstants the rocket model holds for every design.
| Assumed | Value |
|---|---|
| Pump efficiency | 0.72 |
| Open-cycle turbine efficiency | 0.62 |
| Staged turbine efficiency | 0.8 |
| Turbine exit, bar | 2.5 |
| Suction specific speed | 12 |
| Wall limit, K | 800 |
| Fastest shaft, rpm | 50000 |
| Kerosene carbon skin, share of heat passed | 0.55 |
| Jacket, most of the chamber pressure | 0.35 |
| Film share that cuts wall heat by e | 0.04 |
| Film impulse kept | 0.5 |
| Expander jacket ends at area ratio | 12 |
| Battery, MJ per kg | 0.72 |
| Electric drive efficiency | 0.88 |